Intel S1400SP4 BBS1400SP4 User Manual

Product codes
BBS1400SP4
Page of 159
Platform Management Functional Overview 
Intel® Server Board S1400SP TPS 
 
 
Revision 1.0 
Intel order number G64248-001 
 
70 
  On-line help. 
  Display/clear SEL (display is in easily understandable human readable format).  
  Supports major industry-standard browsers (Microsoft Internet Explorer* and Mozilla 
Firefox*). 
  Automatically logs out after user-configurable inactivity period. 
  The GUI session automatically times-out after a user-configurable inactivity period. By 
default, this inactivity period is 30 minutes. 
  Embedded Platform Debug feature - Allow the user to initiate a “diagnostic dump” to a 
file that can be sent to Intel
®
 for debug purposes. 
  Virtual Front Panel. The Virtual Front Panel provides the same functionality as the local 
front panel. The displayed LEDs match the current state of the local panel LEDs. The 
displayed buttons (for example, power button) can be used in the same manner as the 
local buttons. 
  Severity level indication of SEL events. The web server UI displays the severity level 
associated with each event in the SEL. The severity level correlates with the front panel 
system status LED ( “OK”, “Degraded”, “Non-Fatal”, or “Fatal”).  
  Display of ME sensor data. Only sensors that have associated SDRs loaded will be 
displayed.  
  Ability to save the SEL to a file.  
  Ability to force HTTPS connectivity for greater security. This is provided through a 
configuration option in the UI. 
  Display of processor and memory information as is available over IPMI over LAN. 
  Ability to get and set Node Manager (NM) power policies. 
  Display of power consumed by the server. 
  Ability to view and configure VLAN settings. 
  Warn user the reconfiguration of IP address will cause disconnect. 
  Capability to block logins for a period of time after several consecutive failed login 
attempts. The lock-out period and the number of failed logins that initiates the lock-out 
period are configurable by the user. 
  Server Power Control – Ability to force into Setup on a reset.  
6.12.14  Virtual Front Panel 
  Virtual Front Panel is the module present as “Virtual Front Panel” on the left side in the 
embedded web server when "remote Control" tab is clicked. 
  Main Purpose of the Virtual Front Panel is to provide the front panel functionality virtually. 
  Virutal Front Panel (VFP) will mimic the status LED and Power LED status and Chassis ID 
alone. It is automatically in sync with BMC every 40 seconds. 
  For any abnormal status LED state, Virtual Front Panel will get the reason behind the 
abnormal or status LED changes and displayed in VFP side.  
  As Virtual Front Panel uses the chassis control command for power actions. It will not log 
the Front button press event since Logging the front panel press event for Virtual Front 
Panel press will mislead the administrator. 
  For Reset from Virtual Front Panel, the reset will be done by a Chassis control command. 
  For Reset from Virtual Front Panel, the restart cause will be because of Chassis control 
command. 
  During Power action, Power button/Reset button should not accept the next action until 
current Power action is complete and the acknowledgment from BMC is received. 
  EWS will provide a valid message during Power action until it completes the current Power 
action.