2.2 System Level Environmental Limits
The following table defines the system level operating and non-operating environmental limits.
Table 2. System Environmental Limits Summary
Parameter
Limits
Temperature
Operating
ASHRAE Class A2 – Continuous Operation. 10º C to 35º C (50º F to 95º F) with the maximum
rate of change not to exceed 10°C per hour
rate of change not to exceed 10°C per hour
ASHRAE Class A3 – Includes operation up to 40C for up to 900 hrs per year.
ASHRAE Class A4 – Includes operation up to 45C for up to 90 hrs per year.
Shipping
-40º C to 70º C (-40º F to 158º F)
Altitude
Operating
Support operation up to 3050m with ASHRAE class deratings.
Humidity
Shipping
50% to 90%, non-condensing with a maximum wet bulb of 28° C (at temperatures from 25° C
to 35° C)
to 35° C)
Shock
Operating
Half sine, 2g, 11 mSec
Unpackaged
Trapezoidal, 25 g, velocity change is based on packaged weight
Packaged
Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
Vibration
Unpackaged
5 Hz to 500 Hz 2.20 g RMS random
Packaged
5 Hz to 500 Hz 1.09 g RMS random
AC-DC
Voltage
90 Hz to 132 V and 180 V to 264 V
Frequency
47 Hz to 63 Hz
Source Interrupt
No loss of data for power line drop-out of 12 mSec
Surge Non-
operating and
operating
operating and
operating
Unidirectional
Line to earth Only
AC Leads 2.0 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
ESD
Air Discharged
12.0 kV
Contact
Discharge
Discharge
8.0 kV
Air Flow
Operation
R2312BB4 16-103 CFM
R2308BB4 25-152 CFM
R2224BB4 20-126 CFM
R2216BB4 27-152 CFM
R2308BB4 25-152 CFM
R2224BB4 20-126 CFM
R2216BB4 27-152 CFM
Acoustics
Sound Power
Measured
Sound Power
Measured
Power in Watts
<300 W ≥300 W ≥600 W ≥1000 W
Servers/Rack
Mount BA
Mount BA
7.0 7.0 7.0 7.0