27 
Notes:  
1.  For fan speed control in Intel chassis 
2.  Temperature margin from throttling threshold 
3.  Absolute temperature 
4.  PECI value or margin value  
5.  On-die sensor 
6.  On-board sensor 
7.  Virtual sensor 
8.  Available only when PSU has PMBus 
9.  Calculated estimate 
 
The following diagram illustrates the fan speed control structure. 
 
 
 
 
Figure 21. Fan Control Model 
4.3  System Fans 
Five 60x38-mm fans and an embedded fan for each installed power supply, provide the primary airflow for the 
system. The system is designed for fan redundancy when configured with two power supply modules. Should a 
single fan fail (system fan or power supply fan), platform management will adjust air flow of the remaining fans 
and manage other platform features to maintain system thermals. Fan redundancy is lost if more than one fan 
is in a failed state. 
Figure 22. System Fan identification