Intel C2518 FH8065501516710 Data Sheet

Product codes
FH8065501516710
Page of 746
Intel
®
 Atom™ Processor C2000 Product Family for Microserver
September 2014
Datasheet, Vol. 2 of 3
Order Number: 330061-002US
101
Volume 2—System Agent and Root Complex—C2000 Product Family
SoC Error Handling Summary
Memory Controller Channel 1 Errors
D1_0
Read Data Correctable ECC 
Error
Correctable 
Read data is corrected and sent to 
the B-Unit.
FERR/NERR is logged in D-Unit 
and Global Fatal Error Log 
registers:
GFERRSTS
GFFERRSTS
GFNERRSTS
GFFERRTIME
D1_1
Write Data Parity Error
Uncorrectable 
(Fatal)
Write data is written with poisoned 
ECC.
D1_2
Read Data Uncorrectable ECC 
Error (address error, all four 
ECC syndromes are equal 
and correspond to an address 
error)
Read data is sent with bad parity 
to the B-Unit.
D1_3
Read Data Uncorrectable ECC 
Error (general - All other 
non-zero ECC syndromes)
Read data is sent with bad parity 
to the B-Unit.
Memory Controller Channel 2 Errors
D2_0
Read Data Correctable ECC 
Error
Correctable 
Read data is corrected and sent to 
the B-Unit.
FERR/NERR is logged in D-Unit 
and Global Fatal Error Log 
registers:
GFERRSTS
GFFERRSTS
GFNERRSTS
GFFERRTIME
D2_1
Write Data Parity Error
Uncorrectable 
(Fatal)
Write data is written with poisoned 
ECC.
D2_2
Read Data Uncorrectable ECC 
Error (address error, all four 
ECC syndromes are equal 
and correspond to an address 
error)
Read data is sent with bad parity 
to the B-Unit.
D2_3
Read Data Uncorrectable ECC 
Error (general - All other 
non-zero ECC syndromes)
Read data is sent with bad parity 
to the B-Unit.
Table 4-13. Summary of Default Error Logging and Responses (Sheet 3 of 6)
ID
Error
Error Type
(Default 
Severity)
Transaction Response
Default Error Logging
1