Electrical Specifications
Intel
®
 Atom™ Processor E3800 Product Family
112
Datasheet
9.2
Storage Conditions
This section specifies absolute maximum and minimum storage temperature and 
humidity limits for given time durations. Failure to adhere to the specified limits could 
result in physical damage to the component. If this is suspected, Intel recommends a 
visual inspection to determine possible physical damage to the silicon or surface 
components.
Note:
Specified temperatures are not to exceed values based on data collected. 
Exceptions for surface mount re-flow are specified by the applicable JEDEC 
standard. Non-adherence may affect processor reliability.
Component product device storage temperature qualification methods may follow 
JESD22-A119 (low temperature) and JESD22-A103 (high temperature) standards 
when applicable for volatile memory.
Component stress testing is conducted in conformance with JESD22-A104.
The JEDEC J-JSTD-020 moisture level rating and associated handling practices 
apply to all moisture sensitive devices removed from the moisture barrier bag.
9.2.1
Post Board-Attach
The storage condition limits for the component once attached to the application board 
are not specified. Intel does not conduct component-level certification assessments 
post board-attach given the multitude of attach methods, socket types, and board 
types used by customers.
Provided as general guidance only, board-level Intel-branded products are specified 
and certified to meet the following temperature and humidity limits:
Non-Operating Temperature Limit: -40 °C to 70 °C
Humidity: 50% to 90%, non-condensing with a maximum wet-bulb of 28 °C
Table 64. Storage Conditions Prior to Board Attach 
Symbol
Parameter
Min
Max
Tabsolute storage
Device storage temperature when 
exceeded for any length of time.
-25 °C
125 °C
Tshort term storage
The ambient storage temperature and 
time for up to 72 hours.
-25 °C
85 °C
Tsustained storage
The ambient storage temperature and 
time for up to 30 months.
-5 °C
40 °C
RHsustained storage
The maximum device storage relative 
humidity for up to 30 months. 
60% @ 24 °C