Microsoft TM--1104-3 User Manual

Page of 21
 
 Size А3 /А4  
Signature
 and
 Data
 
 
Invent N o
f dou
bl
 
 
Subst. of inv
ent 
N
 
 
Signature
 and
 Data
 
 
Invent N o
f orig
.
 
 
Light-up of one of the LEDs on the ТМ-1304 No.1 – ТМ-1304 No.5 combined modules 
on the ЭМ-1212-1 control module front panel means that either one of the modules 
comprised by the ТМ-1304 combined module is malfunctioning or the TVD working with this 
combined module is out of order. To localize the faulty module, the ACS frame No.1 should 
be output on the TWM screen. 
Light-up of the FUSE diode on the front panel of the ЭМ-1212-1 control module means 
that one of fuses F1-F16 installed on the fifth floor of the device is blown out. To localize the 
faulty fuse, the ACS frame No.1 should be output on the TVM screen. 
Information acquisition and control of the indication LEDs of the ЭМ-1212-1 control 
module is performed by the microcontroller and PLIC of the ACS. The ЭМ-1212-1 control 
module is installed in the middle of the second floor of the device. The device door has a 
glassy window opposite to the ЭМ-1212-1 control module thereby allowing observation on 
the state of the TV-complex when the door is closed. 
 
 
1.1.4.5 Chronometrical Information Input System 
 
The chronometrical information input system receives chronometrical data via 
separate serial channels from device "Гном-2МЭ", transmits it to the external ТМ-1213 
terminal module for mixing into the video signal during video recording and displays this data 
on the screen of the ВС-2 TVM. 
The main unit of the chronometrical information input system is the ЭМ-1242 interface 
unit. The signals of the main and reserved channels of device "Гном-2МЭ" are supplied to 
the interface unit via connectors Х40 and Х41. The MC and PLIC of the ЭМ-1242 interface 
unit perform processing of these signals, reception of the incoming arrays containing 
chronometrical information and writing the data to the internal RAM of the PLIC. 
On request from the ЭМ-1209-1 controller the MC forms a reply array that is 
transferred to the ЭМ-1209-1 controller via a RCLI channel. 
The  ЭМ-1209-1 controller periodically interrogates the ЭМ-1242 interface unit, forms 
data arrays containing date and time and transfers them to the ТМ-1213 terminal module 
and  ЭМ-1211 diagnostics module. The latter displays the date and the time received 
from each of the "Гном-2МЭ" channels in ACS frame No.1. In case of absence of the 
information in one of the "Гном-2МЭ" channels, dashes are displayed in ACS frame 
No.1. 
 
 
1.1.4.6 Power Supply System 
 
 
The power supply system provides secondary feeding voltages for the units and 
modules incorporated by the device as well as some other units of the TV-complex. 
The power supply system comprises the following device modules: 
- assemble unit (A1); 
- interference rejection filters, the ФСП-3В (A2 - A7); 
- power supply unit, the ЭМ-1213 (A61, A71, A72); 
- fuses F1 - F16; 
- power supply cells that are parts of the ЭМ-1204-1 and ЭМ-1205-1 videoswitch 
modules,  ЭМ-1209-1 controller, ЭМ-1211 diagnostics module, ЭМ-1212-1 control module 
and ЭМ-1242 interface unit. 
The three-phase feeding voltage 220 V, 50 Hz from the ЩР-03 switchboard is 
supplied to the device via a cable through connector XP1 and the assembly unit (A1). The 
device is switched on with toggle switch POWER. The three-phase voltage form the switch 
arrives to the indicator lamps through the three fuses and then - to PCB XT1 of the assembly 
unit. The switch and the fuses are found under the drop cover on the assembly unit front 
panel. The lamps indicating presence of feeding voltage 220 V,50 Hz are mounted on the 
assembly unit front panel. 
The three-phase feeding voltage 220 V, 50 Hz from assembly unit PCB XT1 through 
PCB XT1 of the device is supplied to the ФСП-3В interference rejection filters (A2 - A7) and 
then – to the ЭМ-1213 power supply units (A61, A71, A72). The ЭМ-1213 power supply units 
are connected to different phases of the three-phase mains. 
Each of the ЭМ-1213 power supply units has six galvanically decoupled d.c. outputs 
with the following parameters: 
- one 27 V output with a current of up to 4 A; 
- one 27 V output with a current of up to 2 A; 
- four 6 V outputs with a current of up to 2 A. 
All the d.c. power supplies in the ЭМ-1213 power supply units have overcurrent and 
short-circuit protections that are automatically reset when the overload conditions are 
removed. 
The 6 V supply voltages produced by the ЭМ-1213 power supply units are used for 
feeding the modules of the device. The feeding voltage of plus 6 V is provided by connecting 
the negative terminals of the 6 V power supply units to the common bus, whereas for 
obtaining a feeding voltage of minus 6 V the plus 6 V power supply units are connected vice 
versa. The 6 V supply voltages are supplied to the device modules through PСB AP2 of the 
device. 
All the device modules that are supplied with the plus 6 V and minus 6 V voltages are 
fed from two or three ЭМ-1213 power supply units simultaneously. This ensures operability of 
the device in case of failure of one of the ЭМ-1213 power supply units. 
The modules consuming the plus 6 V and minus 6 V voltages contain power supply 
cells that form their own feeding voltages, provided at least one of the ЭМ-1213 power supply 
unit voltages is present. The internal supply voltages of the consuming modules are 
connected to the ЭМ-1211 diagnostics module inputs for control. 
The BC-2 TVM is fed from the ЭМ-1213 power supply unit (A72) with the plus 27 V 
voltage. The ЭМ-1239 power supply installed into the BC-2 TVM produces its own supply 
voltages of plus 12 V and plus 5 V. 
The plus 27 V voltage from the other outputs of the ЭМ-1213 power supply unit is 
distributed among various units and modules of the TV-complex, passing through PCB AP1 
and fuses F1-F16 to the output connectors of the device. The fuses protect the power 
supplies against short-circuits in each of the loads. The fuses are installed on a panel on the 
fifth floor of the device. There is a LED near each of the fuses indicating presence of the plus 
27V voltage on the fuse output. 
The external loads of the plus 27 V supply voltage of the ЭМ-1213 power supply units 
are shown in Table 3. 
 
 
 
 
 
 
 
 
 
 
 
 
P. P. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Rev. P.  Dokument 
Signature 
Data 
ТЭ3.623.912-03РЭ
 
 
 
 
ТЭ3.623.912-03РЭ
 
Rev. P.  Dokument 
Signature Data
22
21