Bunn Ice Tea Maker AFPO-3 User Manual

Page of 25
4
CLEANING
RECOMMENDED WEEKLY CLEANING:
This should be done in conjunction with the recommended weekly cleaning of your machine. The Hoppers must 
be empty before starting.
1.  Prepare a 1 gallon cleaning solution consisting of 1 gallon of hot water and a sanitizing cleaner which contains 
3-5% chlorine based sanitizer. Mix per manufacturers instructions
2.  Remove connectors from each concentrate container and place them directly into the cleaning solution. 
3.  Energize each refill station and allow the cleaning solution to pump through the system into the hoppers. The 
cleaning procedure should remove the color stains from the tubing. If not, prepare another gallon of cleaning 
solution and repeat.
4.  After the cleaning solution has been pumped into the hoppers, rinse the cleaning solution container with hot 
water.
5.  Fill the cleaning solution container with hot water. Energize each refill station and rinse thoroughly. The amount 
of clean hot rinse water should equal the amount of cleaning solution pumped through the system.
6.   Empty the hoppers of your machine and follow the recommended cleaning instructions.
 
NOTE: The hoses should be checked monthly for deterioration, cracks and possible discoloration from some 
concentrates. Replace the tubing when necessary.
MIX RATIO ADJUSTMENTS
1.  Remove the top access panel.
2.  Connect the test hose to the “WATER OUTPUT” to be adjusted.
3.  Connect the provided hose (or other suitable water hose) to the “WATER INPUT”.
4.  Ensure water regulator is set at 20 psi(137.9 kPa).  Press the “TEST OUTPUT” switch and while water is 
flowing from the test hose, check that the gauge reads 20. 
5.  Place a one-cup container under the test hose. Press the “TEST OUTPUT” switch, and carefully measure and 
note the elapsed time from when water first flows form the test hose to when one cup of water has been 
dispensed. Hoses and tubing should be primed and free of substantial air spaces and/or bubbles prior to 
calibration.
6.  Compare results with chart or formula below.
7.  If the time observed is too short or long, turn the needle valve clockwise or counterclockwise, respectively, 
a little at a time. Repeat from the preceding step until correct.
41093 040408