Dodge SP600 Series Data Sheet

Page of 4
Aggregate/Cement
Food
Mining
Forest/Paper
Petro/Chem
Unit/Baggage 
Handling
HVAC/Industrial Air 
Handling
Environmental/Fluid 
Power
Automotive
Metals
SP600
DA
TA SHEET
SP600 Series of AC 
Drives from 0.5 to 200 
Horsepower
A full-featured industrial AC drive 
suitable for wall, machine, flange, and 
washdown mounted installations
The SP600 provides the benefits of 
more expensive full-featured drives in a 
compact, versatile, and cost effective 
design. Multiple enclosure/packaging 
options along with a drive mounted 
graphical keypad and embedded 
braking circuitry make this drive very 
versatile. The wide range of network 
options available for this product will allow 
you to maximize data acquisition, speed 
control and application flexibility.
Features/Specifications
•  Control Modes
 
-   Volts/Hertz
 
-   Sensorless Vector Control
 
  Each method can operate either a single or 
multi-motor application from one SP600. SVC 
is limited to mechanically coupled identical 
motors.
•  Input Voltages/Power Ratings
 
-   200, 208, 240 (0.5 to 10 HP)
 
-   380, 400, 415, 480 (0.5 to 200 HP)
 
-   575 (0.5 to 150 HP)
1
•  Switching Frequency
 
-   Full HP rating at 50°C for (45° for 50 HP;  
40° for 200 HP):
 
  • 4 kHz Frames A - D
 
  • 4 kHz Frames 2 -5
 
  • 4 kHz Frame 6 (2 KHz for 200 HP)
 
-   Derating may apply for higher switching 
frequencies
•  Zero-stacking (side by side) panel mounting 
possible for all frames.
 
575 VAC models are UL and cUL only
•  Terminal Block Control
 
-   6 configurable digital inputs
 
-   Up to 8 pre-set speeds
 
-   Start/Stop, Forward/Reverse,Auto/Manual, 
Jog, Preset Speed, Function Loss, ProcessPI 
Control, etc.
 
-   2 Analog inputs
 
-   1 Analog output
 
-   2 Relay outputs, form C contacts.
•  Drive Serial Interface
 
-   PC configuration and monitoring of a single 
drive or multiple drives when using V*S Utilities 
Software.
•  Overload Protecting
 
-   Intelligent Thermal Management (ITM
) system 
can reduce carrier frequency or trip the drive in 
overtemp conditions.
 
-   UL and NEC approved electronic motor 
overload protection.
•  Enclosures/Mounting
 
-   Wall or machine mount NEMA 1 (IP20)
 
-   Flange mount NEMA 1 (IP20)
 
-   See RAPS-958-2 for NEMA 4x/12
• Internal Braking transistor as standard (optional 
Frames 4, 5, and 6) requires optional drive 
mounted or externally mounted braking resistor
 
-   Drive mounted resistor available for Frames A, 
B, C, D, and 2
AC DRIVES