TROUBLESHOOTING
Replacing An Ionizing Wire
If an ionizing wire should break, it can be
replaced as follows:
1. Remove all pieces of broken wire.
Make sure supports at each end are in
good condition and not bent out of
shape.
2. Hook the new wire onto the support at
one end.
3. Hold your finger against the support at
the other end and hold the ionizing
wire between thumb and forefinger as
shown or use needle nose pliers. Press
on spring and on wire loop until it slips
over the end of the support. Make sure
wire is securely anchored at each end.
Support
Ionizing
Wire
 INDICATION
SERVICE CHECKS
ACTION
None
None
AC Power is not being supplied to air cleaner.
1. Check that power cord is properly connected to 
power pack and to outlet.
2. Check for voltage at air cleaner outlet box. If 
none, check fuse or circuit breaker at power 
input line.
3. Check that fuse in power pack is not blown
4. Check for shorted collecting cell by installing 
power door with collecting cells removed and 
only pre-filter installed. If green light turns ”ON" 
cell is shorted.
5. Check for dirt or blockage in air sensor tube.
6. Check that pre-filter is installed and not 
damaged.
1. Check for dirty collecting cells. Check cells for any 
foreign object that might be lodged between plates 
of cell.
2. Check cells for broken ionizing wires, cracked 
insulator, or bent plates.
3. All ionizing wires must be completely clean with no 
dust build-up on wires.
On/Off switch “ON”
Green light “OFF”
Blower Off
On/Off switch “ON”
Green light “ON”
Blower On
On/Off switch “ON”
Green light “OFF”
Blower On
On/Off Switch “ON”
Green light flickering
Blower On
Normal Standby Operation.
Normal Operation.
1. Make proper power cord connections.
2. Replace fuse or reset circuit breaker.
3. Replace Fuse.
4. Wash cells. If short is not corrected, 
call for service.
5. Clean air sensor tube.
6. Replace damaged filter
1. Remove cells and wash thoroughly.
2. Replace broken ionizing wires. 
Replace cell if insulator cracked or 
plates bent.
3. Clean ionizing wires.