Technician Programming Commands – Continued
How to Set the Post-Receiver Off-Hook (ROH) Option
Use the following key sequence to set the post-ROH option:
Press:
#
*
*
<Post-ROH option> #
The < > brackets represent the 1-digit post-ROH option: 
enter:
for continuous ROH tone 
enter:
to turn off ROH tone and periodically check for an 
on-hook condition.
You must enter either or 1, otherwise the FWT will not update or
store this value and the existing stored parameter will remain.  The 
factory default setting is 1.
How to Set the Pulse Dial Option
Use the following key sequence to set the Pulse Dial option:
Press:
#
*
12 
*
<Pulse Dial option> #
The < > brackets represent the 1-digit Pulse Dial option:
enter:
to disable pulse dialing capability 
enter:
to enable pulse dialing capability.
You must enter either or 1, otherwise the FWT will not update or
store this value; the existing factory default setting is 1.
How to Initiate a Ring-Back Request
Use the following key sequence to initiate an immediate Ring Back:
Press:
#
*
13 
#
There is no Ring Back value to be entered; the command activates
when the phone is placed on-hook. 
How to Restore the Factory Default Settings
Use the following key sequence to restore the factory default settings:
Press:
#
*
15 
#
There is no Restore Defaults value to be entered; the command acti-
vates immediately. If you enter a value, it will be invalid and the FWT
will not restore the factory defaults. Note: NAM (Phone Number Setup)
data is not affected by this command and will not be changed.
How to Enable/Disable the Zero Dial Delay Option 
Use the following key sequence to set the Zero Dial Delay option:
Press:
#
*
21 
*
<Zero Dial Delay option> #
The < > brackets represent the 1-digit Zero Dial Delay option:
enter:
to disable Zero Dial Delay option 
enter:
to enable Zero Dial Delay option
You must enter either or 1, otherwise the FWT will not update or
store this value; the existing stored parameter will remain. The factory
default setting is 1.