SAM4S ER-380 User Manual

Page of 187
ER-380 / ER-380M 
Program Mode Programming   
  149 
Group Programming 
20 Group totals are available to accumulate totals of individual PLUs that are assigned to each group.    Each 
PLU can be assigned to one, two or three different groups. 
•  Use program 900 to assign a group status, i.e. a group can be set to not add to the 
total of all groups, or a group can be used to designate like items for kitchen 
printer assignment.     
•  Use program 910 to assign a unique descriptor for each group, so that the group 
may be easily understood on the group report.     
Programming Group Status - Program 900 
1.  Turn the control lock to the P position. 
2.  To begin the program, enter 9 0 0, press the SBTL key. 
0
SBTL
0
9
 
3.  Enter the number of the group you wish to program; press the X/TIME key.     
 
 
X/TIME
 
 
4.  Enter an option digit from the table below, press the SBTL key. 
 
Address OPTION 
VALUE  =  SUM 
Group total is added to the total of all 
groups on the Group report? 
Yes = 0 
No = 1 
 
N1 
Send to kitchen printer?   
Yes = 2 
No = 0 
 
 
No Choice 
KP PORT#: R (print a kitchen requisition) 
KP PORT#: 1 
N2 
KP PORT#: 2 (ER-380M Only) 



 
 
N3 
Print RED on KP? 
Yes = 1 
No = 0 
 
 
 
N2 
SBTL
N1
N3
 
5.  To program additional groups, repeat from step 3, or press the CASH key to 
finalize the program. 
CASH