77/75/23/21 English Instruction Sheet
Page 
6
Continuity Test ( 
R
 )
RANGE
CAT  
CAT  
+
_
RANGE
CAT  
CAT  
+
_
hc8f.eps
If continuity exists (resistance < 210 
Ω
 for Models 21/75 and
<270 
Ω
 for Models 23/77), the beeper sounds continuously. The
meter beeps twice if it is in Touch Hold
 mode.
Current (
?
 
A
)
W
 Warning
To avoid injury, do not attempt a current
measurement if the open circuit voltage exceeds the
rated voltage of the meter.
To avoid blowing an input fuse, use the 10 A jack until you are
sure that the current is less than 300 mA.
Turn off power to the circuit. Break the circuit. (For circuits of
more than 10 amps, use a current clamp.) Put the meter in series
with the circuit as shown and turn power on.
RANGE
_
CAT  
CAT  
+
+
1
2
4
3
A