BMC Heat Pump GTA3600UD1AA User Manual

Page of 54
Manual 2100-537
I
 
Page 
46 of 54
Manual
2100-537G
Page
44 of 52
Heat
Gen.
Power Failure
Blown Fuse or Tripped Breaker
Faulty Wiring
Loose Terminals
Low Voltage
Defective Contacts in Contactor
Compressor Overload
Potential Relay
Run Capacitor
Start Capacitor
Faulty Wiring
Loose Terminals
Control Transformer
Low Voltage
Thermostat
Contactor Coil
Pressure Controls (High or Low)
Indoor Blower Relay
Discharge Line Hitting Inside of Shell
Bearings Defective
Seized
Valve Defective
Motor Wingings Defective
Refrigerant Charge Low
Refrigerant Overcharge
High Head Pressure
Low Head Pressure
High Suction Pressure
Low Suction Pressure
Non-Condensables
Unequalized Pressures
Solenoid Valve Stuck Closed (Htg)
Solenoid Valve Stuck Closed (Clg)
Solenoid Valve Stuck Open (Htg or Clg)
Leaking
Defective Valve or Coil
Plugged or Restricted Metering Device (Htg)
Scaled or Plugged Coil (Htg)
Scaled or Plugged Coil (CLg)
Water Volume Low (Htg)
Water Volume Low (Clg)
Low Water Temperature (Htg)
Plugged or Restricted Metering Device (Clg)
Fins Dirty or Plugged
Motor Winding Defective
Air Volume Low
Air Filters Dirty
Undersized or Restricted Ductwork
Auxillary Heat Upstream of Coil 
Compressor 
W
il
l Not Run    
       
     
No Pow
er at Contact
or






Compressor 
W
il
l Not Run    
       
Pow
er at Contactor






Compressor 
"Hums
"   
       
       
       
But W
ill Not 
Start







Compressor 
Cyc
les on Ov
erload
















Thermost
at Check
 Light
       
       
    
Lite-Lock
out 
Relay

Compressor 
Off on High  
       
    
Pressure Control










Compressor 
Off on Low
    
       
Pressure Control







Compressor 
Noisy


Head Pressure T
oo High









Head Pressure T
oo Low





Suction P
ressure Too High



Suction P
ressure Too Low










I.D. Blow
er W
ill Not
 Start





I.D. Coil 
Frosting or Ic
ing





High Compress
or Amps













Ex
cessiv
e W
ater Us
age


Compressor 
Runs Continuously
  
    
–  No Cooling







Liquid Refrigerant Fl
ooding Back
 
 
To Compres
sor




Compressor 
Runs Continuously
  
    
–  No Heating






Rev
ersing Valv
e Does
 Not Shift



Liquid Refrigerant Fl
ooding Back
 
 
To Compres
sor





Aux
. Heat on I.
D. Blow
er Off





Ex
cessiv
e Operati
on Costs









Ice in W
ater 
C
oi
l





            Heating Cycle
A
UX.
Cooling 
Cycle
                                             Heating or Cooling Cycles
I
n
door Blower 
M
otor 
and  Coi
l
INDOOR SECT
ION
POW
ER SUP
PLY
W
ater 
S
olenoid
R
ev
Valv
e
W
ater Coi
l
W
A
T
E
R COIL SE
CT
IO
Line V
oltage
Control Ci
rcuit
Compressor
Refri
gerant Sy
stem
QUICK 
REFERENCE 
TROUBLESHOOTING 
CHART 
FOR 
WATER 
TO 
AIR 
HEAT 
PUMP

Denotes 
common 
cause

Denotes 
occasional 
cause
QUICK REFERENCE TROUBLESHOOTING CHART FOR W
ATER T
AIR HEA
T PUMP