Blodgett KLS-20G User Manual

Page of 39
11
4.0  OPERATION
WARNING:  In the event of main burner ignition failure, a 5 minute
purge period must be observed prior to re-establishing ignition
source.
WARNING:  In the event you smell gas, shut down equipment at the
main shut off valve and contact the local gas company or gas
supplier for service.
CAUTION:  If you smell gas during the lighting procedure,
immediately shut off the gas supply until the leak has been
corrected.
GAS CONTROL INSTRUCTIONS:
Appliance does not require “Lighting” the pilot with a flame.
A.  STARTUP
1.  Turn thermostat to “OFF” position and power switch to “OFF” position.
2.  Open control panel access door located on right side at bottom.
3.  Turn dial on combination control to “ON” position by rotating control knob counterclockwise.
(NOTE:  Any gas service valves exterior to the unit should be open.)
4.  Turn “POWER” switch to “ON” position.
5.  Set “COOK TEMP” to desired setting.  The red “COOKING” pilot will be on until desired
setting has been reached.
6.  At this time the spark igniter will begin sparking at the pilot until the pilot is ignited, or for
ninety seconds (an audible clicking sound will be evident).
7.  When the pilot is ignited the spark igniter will automatically stop and within 15 seconds
main burner gas will come on.  If ignition does not occur, after a total of ninety
seconds, the unit will lockout, shutting off all gas although the spark igniter will
continue to spark. New installations (where there may be a considerable amount of air
Contact the factory, the factory representative or a local service company to perform
maintenance and repairs should the appliance malfunction.