HP B.06.X User Manual

Page of 78
Installing and Configuring PPU Software
Configuring PPU Software
Chapter 3
29
Configuring PPU Software
After you have successfully installed the PPU B.06.x software, using the 
swinstall
 command, you need to configure the PPU 
https
 client 
connection to the utility meter. The utility meter must be configured on 
every partition, including virtual partitions.
NOTE
The following configuration procedure assumes your utility meter has 
been installed on the PPU system’s network by your HP service 
representative. If the utility meter is not installed, contact your HP 
service representative.
There can be up to four steps to configure your PPU system, depending 
on whether or not your network uses a proxy server, and if you desire to 
specify a name other than your system’s hostname as the system 
identifier.
At a minimum, the name of the utility meter must be set. The four steps 
to configure the PPU software are:
Step 1. Configure the hostname of the utility meter (required)
Step 2. Configure the hostname of the proxy server (if necessary)
Step 3. Configure the proxy server’s username and password (if required by the 
proxy server)
Step 4. Configure the system identifier (if desired)
Configuring the Utility Meter (required)
To set the hostname of the utility meter, execute the following command:
/usr/sbin/ppuconfig -m meter
Where 
meter
 is the fully qualified hostname or IP address of the utility 
meter.