Integrating SAP DB/MaxDB and Data Protector
Configuring the Integration
Chapter 3
275
Then execute the following command:
On HP-UX:
/opt/omni/lbin/util_sapdb.exe \
[-homedir <SAPDB_independent_program_directory>] \
-config <Instance_Name> <username> <password>
On other UNIX:
/usr/omni/bin/util_sapdb.exe \
[-homedir <SAPDB_independent_program_directory>] \
-config <Instance_Name> <username> <password>
Windows
In a cluster environment, the environment variable 
OB2BARHOSTNAME
 
must be defined as the virtual hostname before running the 
util_sapdb.exe
 command (on the client). The 
OB2BARHOSTNAME
 
variable is set as follows:
set OB2BARHOSTNAME=<virtual_hostname>
Execute the following command on the SAP DB/MaxDB Server system:
<Data_Protector_home>\bin\util_sapdb.exe \
[-homedir <SAPDB_independent_program_directory>] \
-config <Instance Name> <username> <password>
The parameters are defined as follows:
<SAPDB_independent_program_directory>
  The SAP DB/MaxDB 
independent program path 
parameter. This parameter is the 
independent program path directory 
specified during the installation of 
the SAP DB/MaxDB application on 
the SAP DB/MaxDB Server.
This parameter is optional. If it is not 
specified, the directory is detected 
automatically.
<Instance_Name>
  
The name of the SAP DB/MaxDB 
instance to be configured.
<username>
  
The username of the SAP DB/MaxDB 
user created or identified as 
described in “Configuring Users” on 
page 263.