Maintenance 
14  
Rev 
70008-20071026 
Spark Arrester 
1.  Allow the engine to cool completely 
before servicing the spark arrester. 
2.  Remove the two screws holding the 
cover plate which retains the end of the 
spark arrester to the muffler. 
3.  Remove the spark arrester screen. 
4.  Carefully remove the carbon deposits 
from the spark arrester screen with a 
wire brush. 
5.  Replace the spark arrester if it is 
damaged. 
6.  Position the spark arrester in the 
muffler and attach with the two screws. 
Cleaning 
 CAUTION 
DO NOT spray engine with water. 
Water can contaminate the fuel system. 
 
Use a damp cloth to clean exterior surfaces 
of the engine. 
Use a soft bristle brush to remove dirt and 
oil. 
Use an air compressor (25 PSI) to clear dirt 
and debris from the engine. 
Adjustments 
The air-fuel mixture is not adjustable. 
Tampering with the governor can damage 
your generator and your electrical devices 
and will void your warranty. CPE 
recommends that you contact our service 
line at 1-877-338-0999 for all other service 
and/or adjustment needs. 
Maintenance Schedule 
Follow the service intervals indicated in the 
schedule below.  
Service your generator more frequently 
when operating in adverse conditions.  
Contact our help line at 1-877-338-0999 to 
locate the nearest Champion Power 
Equipment certified service dealer for your 
generator or engine maintenance needs. 
 
Every 8  hours or daily 
  
Check oil level 
  
Clean around air intake and muffler 
First 5 Hours 
  
Change oil 
Every 50 hours or every season 
  
Clean air filter 
  
Change oil if operating under heavy load 
or in hot environments 
Every 100 hours or every season 
  
Change oil 
  
Clean/Adjust spark plug 
  
Check/Adjust valve clearance * 
  
Clean spark arrester 
  
Clean fuel tank and filter * 
Every 3 years 
 
Replace fuel line 
 
 
*  To be performed by knowledgeable, 
experienced owners or Champion Power 
Equipment certified service dealers 
 
Generator Maintenance 
Make certain that the generator is kept clean 
and stored properly. Only operate the unit 
on a flat, level surface in a clean, dry 
operating environment. DO NOT expose the 
unit to extreme conditions, excessive dust, 
dirt, moisture or corrosive vapors.  
 CAUTION 
DO NOT use a garden hose to clean the 
generator. 
Water can enter the generator through the 
cooling slots and damage the generator 
windings. 
 
Use a damp cloth to clean exterior surfaces 
of the generator. 
Use a soft bristle brush to remove dirt and 
oil. 
Use an air compressor (25 PSI) to clear dirt 
and debris from the generator.  
Inspect all air vents and cooling slots to 
ensure that they are clean and unobstructed.