Texas Instruments Evaluation Module PCM1795 User Manual

Page of 24
1.3
System Requirements
1.4
Electrostatic Discharge Warning
1.5
Function Control for DAI Interface Format
1.6
Reset Operation
www.ti.com
System Requirements
The DEM-DSD1796/PCM1795/PCM1796/PCM1798 EVM has the following requirements:
• ±
15-V analog power supply at AVCC+, AVCC–, and GND
5-V DAC power supply at VCC and GND
S/PDIF input (sampling rate f
S
is up to 96 kHz) connected at the coaxial or optical connector
RCA analog output connected at CN103 (Lch) and CN104 (Rch); analog full-scale output level is 4.5
V
RMS
.
PC connected to printer connector CN003 for demonstration software operation (if necessary)
Appropriate test module:
DEM-PCM1795: for PCM1795
DEM-PCM1796: for PCM1796
DEM-DSD1796: for DSD1796
DEM-PCM1798: for PCM1798
Many of the components on the DEM-DSD1796/PCM1795/PCM1796/PCM1798 EVM are susceptible to
damage by electrostatic discharge (ESD). Customers are advised to observe proper ESD handling
precautions when unpacking and handling the EVM, including the use of a grounded wrist strap at an
approved ESD workstation.
CAUTION
Failure to observe ESD handling procedures may result in damage to EVM
components.
SW001, SW002, and SW003 are switches for controlling the audio interface format of the DAI receiver
CS8414. The default audio interface format of the DSD1796/PCM1795/PCM1796/PCM1798 is I
2
S™
format.
lists the digital audio receiver configuration parameters.
Table 1-1. Digital Audio Receiver Configuration
Receiver Output Data
SW001
SW002
SW003
Format
L
L
L
16- to 24-bit left–justified
L
H
L
16- to 24-bit l2S
16-bit right-justified (or
H
L
H
standard)
18-bit right-justified (or
L
H
H
standard)
Pressing the SW004 pushbutton initiates a reset operation of the CS8414.