Kentrox AI296 User Manual

Page of 404
AI296 Version 9.8x User’s Guide
Link Configuration: Disconnect Options Configuration
6-21
This example displays 
Disconnect when DCD is off
 set to 
On
 and 
Disconnect when a Break 
character is received
 set to 
Off
 for an async link.
Disconnect String
Description
This menu item configures the string the link sends before the link disconnects. The 
following character values apply:
z
<b>
 sends a break signal.
z
<
n
>
 represents the decimal value of an ASCII character. Valid values are 0 to 255.
z
text
 represents the text value in the string.
z
<p 
#
>
 represents a pause control sequence. 
#
 is the number of tenths of seconds 
to pause. Valid values are 1 to 20 (for 0.1 seconds to 2 seconds).
For example, string 
<b>login<13><p 10><b>
 sends:
z
A break signal
z
The text “login”
z
A carriage return
z
A one second pause
z
Another break signal.
Menu Item Type
Data
Link Type Availability
Async
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.12.
2. For 
07 Disconnect string
, enter 
7,
 and the disconnect string. Maximum length is 
80 characters.
Disconnect Options Menu
Link being configured  . . . . . . . . . . . . . . . . . . . . . . . . .      4
Disconnect when DCD is off . . . . . . . . . . . . . . . . . . .    [On]   Off
Disconnect when a Break character is received  . . . . . . . . .     On   [Off]