Kentrox AI296 User Manual

Page of 404
AI296 Version 9.8x User’s Guide
Link Configuration: General Link Properties Configuration
6-29
This example displays 
Link Description
 set to 
New X.25 Link
.
Link Mode
Description
This menu item defines the mode of operation for an X.25 link as normal, passive, or 
extended:
z
Normal mode is used for normal X.25 service.
z
Passive mode allows AI296 to operate with the SCCS application of the AT&T 
5ESS. The SCCS application requires redundant links at the 5ESS. These links 
are called SCC0B and SCC1B. Only one link is active at a time. The 5ESS 
constantly tries to bring up whichever link is idle. If the 5ESS has SCC0B active, it 
will try to bring up SCC1B. If SCC1B comes up, the 5ESS will drop SCC0B and 
send information on SCC1B. Passive mode ensures that either SCC0B or SCC1B 
will be up, but not simultaneously.
z
Extended mode supports passive link capability to the 5ESS over a TCP/IP 
network. Extended mode ensures that either SCC0A or SCC1A will be up but not 
simultaneously and will temporarily take down the corresponding link if 
connections fail or cannot be placed because the corresponding remote link is 
down.
Menu Item Type
Toggle
Link Type Availability
X.25
Configuration in the AI198 Menu System
1. Access Menu 4.2.1114.12.
2. For 
05*Link mode
, enter 
5
 to select 
Normal
Passive
, or 
Extended
. The default is 
Normal
.
X.25 Link Menu
Link to configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Link state . . . . . . . . . . . . . . . . . . . . . . . . . .    [Up]   Down
Link Type . .     Async   [X.25]   HDLC-Bridge    SyncPPP    AsyncPPP    MLT
Interface Type . . . . . . . . . . . . . . . . .     RS-232   [RS-530]   V.35
Link Description  . . . . . . . . . . . . . . ................. New X.25 Link