Link Configuration: General Link Properties Configuration
6-33
Passive Link with Clocking
Description
This menu item enables or disables an X.25 passive link from supplying a clock value 
while the link is in the inactive state.

Note: Old AT&T 5ESS interface cards (TN983) require clocking with the passive link 
set up.
Menu Item Type
Toggle
Link Type Availability
X.25
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.
2. For 
13*Passive Link with Clocking
, enter 
13
 to select 
Enabled
 or 
Disabled
. The 
default is 
Disabled
.
This example displays 
13*Passive Link with Clocking
 set to 
Enabled
.
Configuration in the AI296 Local Menu System
1. Access the X.25 Link Menu.
2. From the X.25 Link Menu, select 
Quick X.25 Menu
. The Quick X.25 Menu appears.
3. For 
Passive Link with Clocking
, select 
Enabled
 or 
Disabled
. The default is 
Disabled
.
>13
                                                                 Menu 4.2.11.12
01 Link number (1-16)--------------------------------------------------------05
02*Link Type (Async, X25, HDLC, SyncPPP, AsyncPPP, MLT)----------------    X.25
03 Link Description------------------------------                   X.25 link 5
04*Link state (Enabled, Disabled)--------------------------------------Disabled
05*Link mode (Normal, Passive, Extended)-------------------------------  Normal
06 Port speed (0 - 128000 bps, 0 is external clocking)-------------------009600
07+X25 LAPB Parameters
08+X25 Parameters
09+Virtual Circuits
10*Hardware Interface (RS232,RS530,V.35)----------------------------------RS232
11+BX25 Configuration
12 Auto Disable Error Limit (0-1000000)---------------------------------0000000
13*Passive Link with Clocking (Enabled, Disabled)---------------------- Enabled