Kentrox AI296 User Manual

Page of 404
AI296 Version 9.8x User’s Guide
Link Configuration: Quick X.25 Configuration
6-67
Link Type Availability
X.25
Configuration in the AI296 Local Menu System
1. Access the X.25 Link Menu.
2. Select 
Quick X.25 Menu
. The Quick X.25 Menu appears.
3. For 
X25 Passive Link Mode
, select 
Normal
Passive
, or 
Extended
. The default is 
Normal
.
4. For 
Passive Link with Clocking
, select 
Enabled
 or 
Disabled
. The default is 
Disabled
.
This example displays 
X25 Passive Link Mode
 set to 
Passive
 and 
Passive Link with 
Clocking
 set to 
Enabled
.
Port Speed
Description
This menu item defines how many bits of data AI296 can transmit per second over a 
link.

Note: There is an aggregate baud rate limitation of 359 kilobits per second for link 
groups 1 to 4, 5 to 8, 9 to 12, and 13 to 16. For example, the total baud rate 
configured for links 1 to 4 must not exceed 359 kilobits per second. If it does, 
then the AI296 disables the links and reports an error.
Menu Item Type
Data
Link Type Availability
X.25
Configuration in the AI296 Local Menu System
1. Access the X.25 Link Menu.
2. Select 
Quick X.25 Menu
. The Quick X.25 Menu appears.
Quick X.25 Menu
Link being configured  . . . . . . . . . . . . . . . . . . . . . . . . .    02
Interface Mode  . . . . . . . . . . . . . . . . . . . . . . .      DTE   [DCE]
Port speed (0=external clocking)  . . . . . . . . . . . . . . . . . . . . 9600
X25 Passive Link Mode . . . . . . . . . . .     Normal   [Passive]   Extended
Passive Link with Clocking  . . . . . . . . . . . . .    [Enabled]   Disabled