Kentrox AI296 User Manual

Page of 404
AI296 Version 9.8x User’s Guide
Link Configuration: X.25 Parameters Configuration
6-81
This example displays 
01*X25 Facilities negotiation
 set to 
ON
.
Configuration in the AI296 Local Menu System
1. Access the X.25 Link Menu.
2. Select 
X.25 Parameters Menu
. The X.25 Parameters Menu appears.
3. For 
X25 Facilities Negotiation
, select 
Enabled
 or 
Disabled
. The default is 
Disabled
.
This example displays 
X25 Facilities Negotiation
 set to 
Enabled
.
X.25 Timer Settings
Description
The X.25 timer settings are configured using eight menu items:
z
T20 restart timer
—Defines the amount of time allowed for receipt of a restart 
confirmation or restart indication after a restart request.
z
T21 call timer
—Defines the amount of time allowed for receipt of call connected, 
clear indication, or incoming after a call request.
z
T22 reset timer
—Defines the amount of time allowed for receipt of a reset 
confirmation or reset indication after a reset request.
z
T23 clear timer
—Defines the amount of time allowed for receipt of a clear 
confirmation or clear indication after a restart request.
z
T24 window timer
—Defines the amount of time allowed for window status 
transmission.
z
T25 data retransmission timer
—Defines the amount of time allowed for T25 data 
retransmission.
z
T26 interrupt timer
—Defines the amount of time allowed for receipt of an interrupt 
confirmation after an interrupt is sent.
z
T28 registration timer
—Defines the amount of time allowed for receipt of a 
registration confirmation after a registration request.
>1
                                                               Menu 4.2.11.12.8
01*X25 Facilities negotiation----------------------------------------------- ON
X.25 Parameters Menu
Link being configured  . . . . . . . . . . . . . . . . . . . . . . . . .    03
X25 Facilities Negotiation  . . . . . . . . . . . . .    [Enabled]   Disabled