Kentrox AI296 User Manual

Page of 404
AI296 Version 9.8x User’s Guide
AI296 Commands: winslc Commands
9-4
winslc Commands
The winslc commands let the user communicate with AI296 from AI198. Use these 
commands to enter data, diagnose problems, and retrieve information from AI296.
Displaying winslc Command Logging
To monitor winslc commands, press CTRL+l when logged into AI198 to turn on 
logging.
Using winslc Commands
To use winslc commands, the user must be logged into AI198 to receive output from 
AI296. AI198 relays the command to AI296, which processes the command and 
sends the result to the system log port (as configured in AI198 Menu 1.1). Valid winslc 
commands are:
From the AI198, you can view the available winslc commands by entering the 
following command:
winslc 
baseport
 help
where 
baseport
 specifies the baseport number of AI296.
Log/Alarm Message Header
To obtain output from winslc commands, enable the activity/alarm log (AI198 Menu 
1.1, menu item 
01*The activity and alarm log is turned
). The first line of the response 
for most winslc commands shows the following standard log/alarm message header:
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
>@AI19807:42:26 081104 Sev=F Base=016 Msg: