Kentrox AI296 User Manual

Page of 404
AI296 Version 9.8x User’s Guide
AI296 Commands: alarm
9-12
alarm
Description
This command:
z
Displays a list of the alarm groups and the overall alarm severity
z
Displays alarms for a specified alarm group or for a specified range of severity 
levels within an alarm group
z
Displays alarms by severity level or for a specified range of severity levels
z
Clears all non-self-clearing alarm groups and the overall alarm severity
z
Clears a specified non-self-clearing alarm group
z
Masks a specified alarm group
z
Unmasks a specified alarm group.
Command Type
shell
Formats
alarm
group
 [ 
range
 ]
-sev [ 
range
 ]
-clear [ 
group 
]
-mask 
group
-unmask 
group
Parameters
group
Defines the group of alarms to display, clear, mask, or unmask. Valid 
values are existing alarm groups. The following parameters is accepted:
range
—Defines a range of alarm severity levels to display. Valid 
values are 
1
 to 
32
. Individual values in the range are separated by 
hyphens (
-
).
-sev
Displays all alarms or a range of alarms based severity level. The 
following parameters is accepted:
range
—Defines a range of alarm severity levels to display. Valid 
values are 
1
 to 
32
. Individual values in the range are separated by 
hyphens (
-
).