Kentrox AI296 User Manual

Page of 404
AI296 Version 9.8x User’s Guide
AI296 Local Menu System: Logging Into AI296
3-4
The following message appears when AI296 is configured to contact a TACACS+ 
server during authentication, but the contact attempt fails:

Note: Five consecutive failed login attempts generate an SNMP trap and a log 
message saying that the login failed. Also, an entry appears in the log file with 
text stating 
Warning: 
x
 
consecutive failed login attempts
 where 
x
 is the number 
of consecutive failed login attempts.
Using an Asynchronous Port for Login
Two tools are required for logging into AI296 using an asynchronous port:
z
A PC with terminal emulation software such as HyperTerminal (included with 
Windows 95/98/2000/XP) or ProComm.
z
Terminal cable with these specifications: null (RS232) cable with DB25 male 
connector for AI296 distribution panel connection and appropriate connector for 
your PC.
To log into AI296 using an asynchronous port:
1. Set the terminal emulation software to the following settings:
z
9600 baud
z
No parity
z
Eight data bits
z
One stop bit
2. Power on AI296.
3. Connect a PC to port 1 on the DP232 distribution panel.

Note: Link 1 on AI296 is enabled and configured for login by default, which 
allows access through the link. AI296 may also be accessed through any 
asynchronous link that is enabled and configured for login.
4. Press ENTER. The login prompt appears. 
5. Enter your user ID. The password prompt appears. 
6. Enter your password. The destination menu appears. You are now logged into 
AI296.
login: test
Password:
Contacting TACACS+ server.  Please wait.
TACACS+ server(s) not responding.