Passive Link Settings
Description
The passive link settings are configured using three menu items. The configurable 
values are:
z
Passive link down state
—Configures standby (DMlock) mode for a passive link. 
When this feature is turned on, a passive link will go into DMlock mode after all 
calls have cleared. When turned off, a passive link will stay up when all calls have 
cleared.
z
Passive link stay inactive timer
—Sets the number of seconds a passive link waits 
for a connection to come up before failing.
z
Passive link standby mode timer
—Configures the amount of time a link remains in 
standby mode before it becomes idle. Immediately after a passive link becomes 
inactive, it goes into the standby (DMlock) mode.
Menu Item Types
Toggle for the 
passive link down state
Data for the 
passive link stay inactive timer
 and the 
passive link standby mode timer
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.
2. For 
09*Bring passive link down when all calls have cleared
, enter 
9
 to select 
ON
 or 
OFF
. The default is 
OFF
.
3. For 
10 Passive link Stay Inactive timer
, enter 
10,
 and a value in seconds for the 
passive link stay inactive timer. The minimum value is 
25
 seconds and the default 
is 
60
 seconds.
4. For 
11 Passive link Standby Mode timer
, enter 
11,
 and a value in seconds for the 
passive link standby mode timer. The minimum value is 
5
 seconds and the default 
is 
25
 seconds.