Echo TC-2100 User Manual

Page of 28
16
M
AINTENANCE
Your ECHO tiller/cultivator is designed to provide many hours of trouble free service. Regular scheduled maintenance will
help your tiller/cultivator achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want
to take your unit to an ECHO Service Dealer for maintenance.  To help you decide whether you want to DO-IT-YOUR-
SELF or have the ECHO Dealer do it, each maintenance task has been graded. If the task is not listed, see your ECHO
dealer for repairs.
SKILL
 
LEVEL
Level 1 = Easy to do. Most required tools come with unit.
Level 2 = Moderate difficulty. Some specialized tools may be required.
Level 3 = Experience required. Specialized tools are required. ECHO recommends
that the unit be returned to your ECHO Dealer for service.
ECHO offers REPOWER
TM
 Maintenance Kits and Parts to make your maintenance job easier. Just below each task
heading are listed the various part numbers required for that task. See your ECHO dealer for these parts.
MAINTENACE
 
INTERVALS
C o m p o n e n t/S y s te m
M a in te n a n c e
P ro c e d u re
D a ily
o r
B e fo re
U s e
E v e ry
R e fu e l
3
M o n th s
o r  9 0
H o u rs
6
M o n th s
o r  3 0 0
H o u rs
Ye a rly
o r  6 0 0
H o u rs
A ir  F ilte r
C le a n/R e p la c e
I /C
R
F ue l  S tra ine r
Ins p e c t/R e p la c e
I
R
F ue l  L ine
Ins p e c t/R e p la c e
I
I
C a rb ure to r
Ins p e c t/R e b uild /R e p la c e
C
R   (1 )
C ho k e   S ys te m
Ins p e c t/R e p la c e
I
C o o ling   S ys te m
Ins p e c t/C le a n
I /C
M uffle r  S p a rk   A rre s to r
C le a n/R e p la c e
I /  C
G e a r  H o us ing
G re a s e
I*
Tine s
Ins p e c t/C le a n
I
R e c o il  S ta rte r  R o p e
Ins p e c t/C le a n
I
F ue l  L e a k s
Ins p e c t/R e p a ir
I
I
S p a rk   P lug
C le a n/R e p la c e
I /  C
R
Ig nitio n  S ys te m
C le a n/R e p la c e
N o  M a inte na nc e  re quire d fo r c o il a nd fly whe e l
S c re w s /N uts /B o lts
Ins p e c t/Tig hte n/R e p la c e
I
I
I  =  INSPECT,  R = REPLACE, C = CLEAN
IMPORTANT -
Time intervals shown are maximum. Actual use and your experience will determine the frequency of
required maintenance.
*Or 50 hours, whichever occurs first.
(1) Replacement will be required for commercial use after 600 hours. For Consumer use, cleaning every 6 months is
required. Cleaning includes Rebuild Kits.