4. Installation
B. Anti-bubbler Installation - 3/8" Feedtube
Install spring guard, fitting nut, and ferrule onto the feedline. Insert feedline into fitting located in
reservoir lid. Insert anti-bubbler into 3/8" feedline. Position feedline so that the anti-bubbler is close
to the bottom of the adhesive bottle.
4.2 Connecting Airlines
Connect the blue 4 mm O.D. airline to the lower fitting/air outlet choke, farthest fitting from the
knob (see Figure 1 item 8). The other end of the airline will be connected to the normally opened
port of a 4-way solenoid valve.
Connect the yellow 4 mm O.D. airline to the upper fitting/air outlet choke closest fitting to the knob
(see Figure 1 item 9). The other end of the airline will be connected to the normally closed port of
a 4-way solenoid valve.
Adapter
Feedline to Valve
4.1 Installing the Anti-Bubbler to .5 liter and 2 liter Reservoirs
Anti-bubbler
The anti-bubbler is inserted at the end of the feedtube which resides in the product reservoir. The
purpose of the anti-bubbler is to minimize the amount of adhesive which will run out of the
feedtube when the reservoir lid is removed to re-fill the product reservoir.
A. Anti-bubbler Installation - 1/4" Feedtube
Install spring guard, fitting nut, and ferrule onto the feedline. Insert feedline into fitting located in
reservoir lid. Insert anti-bubbler into anti-bubbler connection sleeve. Push anti-bubbler connection
sleeve onto 1/4" feedline. Position feedline so that the anti-bubbler is close to the bottom of the
adhesive bottle.
Connection
Sleeve
Adapter
Feedline to Valve