2. CONTROL ELEMENTS AND CONNECTIONS
2.2 Rear panel
ACX450
ACX900
ACX1800
Fig.  2.2:  Rear  panel  connectors
Use  the  balanced  LINE  outputs  (XLR  connections)  to
connect your ULTRACOUSTIC to the inputs of a mixing
desk (only in ACX1800 and ACX900).
With  the  GND  LIFT  (ground  lift)  switch  you  can
disconnect the ground connection between the amplifier
and  the  mixing  desk  (switch  pressed).  This  is  done  to
eliminate buzz or ground loop hum.
You also have the option to take up the audio signal from
the instrument channel at the TUNER output and to feed
it to the tuner. There is a continuous signal at this jack.
Connect  the  supplied  double  foot  switch  to  the
FOOT  SW(ITCH)  jack.  The  foot  switch  enables  you  to
switch  the  effects  of  both  channels  on  and  off
(corresponds to the function of the IN/OUT switch 
).
The CD  IN  input  (RCA)  allows  for  the  connection  of  an
external  stereo  source.  You  can  for  example  play  your
favourite tune while being accompanied with music from
a CD, MD or a drum machine.
+
 MIC INSERT: The microphone channel is equipped
with  a  serial  loop  connection  for  external  effects  units.
To do this, connect the SEND jack 
 with the input of
your effects unit. Connect the output of the external effects
unit to the RETURN jack 
 of the ULTRACOUSTIC.
+
 INST(RUMENT) INSERT: The instrument channel is
also  equipped  with  a  serial  loop  connection  for  external
effects  units. 
  is  the  respective  SEND  connector
(output)  and 
  is  the  respective  RETURN  connector
(input).
+
The  INSERT  SEND  connector  can  also  be  used  as
parallel  outputs,  e.g.  to  individually  feed  the  signal
of  one  channel.  As  long  as  the  RETURN  connector
is  not  used,  the  internal  signal  flow  is  not
interrupted.
Fig. 2.3: Standard IEC power receptacle,
fuse  holder  and  serial  number  (rear  panel)
Power  is  supplied  via  an  IEC  connector.  The  matching
cable is provided with the unit.
FUSE  RETAINER/VOLTAGE  SELECTOR:  Please  make
sure  that  the  voltage  indicated  by  the  voltage  selector
matches the local voltage before you connect the unit to
the main power supply. Always replace blown fuses with
fuses  of  the  same  type  and  rating.  Some  units  feature  a
fuse  retainer  in  which  a  selection  between  230  V  and
120 V is possible. Please be aware: When using your unit
outside of Europe with 120 V, a fuse with a higher rating is
required.
SERIAL NUMBER.