Horstmann C-Stat ZW Installation Guide

Page of 16
2
Installing the ASR-ZW receiver
The ASR-ZW receiver should be located as near as is 
practical to the boiler or zone valve to be controlled, as 
well as a convenient mains electricity supply. To remove 
the wall plate from the ASR-ZW undo the two retaining 
screws located in the underside, the wall plate should 
now be easily removed. Once the wall plate has been 
removed from the packaging please ensure the ASR-
ZW is resealed to prevent damage from dust, debris etc.
The wall plate should be fitted with the retaining screws 
located at the bottom and in a position which allows a 
total clearance of at least 50mm around the ASR-ZW 
receiver.
Direct Wall Mounting
Offer the plate to the wall in position where the ASR-ZW 
is to be mounted and mark the fixing positions through 
the slots in the wall plate. Drill and plug the wall, then 
secure the plate into position. The slots in the wall plate 
will compensate for any misalignment of the fixings.
Wall Box Mounting
The wall plate may be fitted directly on to a single gang 
flush wiring box complying with BS4662, using two M3.5 
screws. The receiver is suitable for mounting on a flat 
surface  only;  it  is  not  suitable  for  mounting  on  an 
unearthed metal surface.