Behringer Eurolight LD6230 User Manual

Page of 11
5
EUROLIGHT LD6230 User Manual
2.  Control Elements
Various LD6230 control elements are described in this chapter. All controls and 
connectors are described in detail, and you also get useful advice on how to use 
them in different applications.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Fig. 2.1: EUROLIGHT LD6230’s front panel
(1) 
Ventilation openings are located on the front panel. Their position at 
the front assures that hot air does not enter the inside of your rack, 
causing equipment failure or damage.
◊ 
To ensure that your dimmer pack runs smoothly even under full 
load, you have to make sure that there is enough distance to other 
heat-emitting equipment. 
(2) 
There is an automated fuse for each of the six dimmer circles. These fuses 
engage in the event of overload or short circuit.
(3) 
Use the CHANNEL key to shift between the six dimmer channels. When used 
in combination with the CONFIG key (see  
(5)
), you can select different 
operating modes (DMX, ANALOG and MANUAL). 
(4) 
Use the UP and DOWN keys to navigate through individual menus.
(5) 
The CONFIG key is used to activate the configuration mode (see ch. 2.1) 
and to select individual menus. When used in combination with the 
CHANNEL key (see  
(3)
), you can select different operating modes.
(6) 
The LEDs to the left of the display have two purposes: supply phase status 
indication (L1, L2 und L3) and indication of the operating mode you selected 
(DMX, ANALOG and MANUAL). 
(7) 
The 3-digit DISPLAY shows the values to be edited. 
(8) 
The LEDs to the right of the display relate to the individual menus in the 
configuration mode. Depending on the selected function, the corresponding 
LED lights up.
(9)
(10)
(12)
(14)
(13)
(11)
(15)
Fig. 2.2: EUROLIGHT LD6230’s rear panel
(9) 
When your LD6230 works in DMX mode, use the 5-pole DMX512 IN-XLR 
connector to connect DMX512 control signals (see ch. 2.2 “DMX mode” and 
ch. 4.1 “Digital DMX connector”).
(10) 
You can relay the DMX control signal to additional dimmer packs by using 
the 5-pole DMX512 OUT XLR connector. If the dimmer is at the terminal end 
of a DMX chain, place a terminator at the DMX output of the dimmer pack to 
avoid signal bounce (use a terminator with the resistance of 120 Ω between 
pins 2 and 3).
(11) 
You can connect an analog 0 - 10 V control signal to the 8-pole ANALOG IN 
DIN connector (see ch. 2.3 “ANALOG mode” and ch. 4.2 “Analog connector”).
(12) 
This is the cable slot for connecting your lighting equipment 
(see Installation Instructions).
(13) 
This is the cable slot for the power supply (see Installation Instructions).
(14) 
The cooling fan is located here.
(15) 
SERIAL NUMBER. Please take a few minutes and send us the completely 
filled out warranty card within 14 days of the date of purchase. 
Otherwise, warranty claims may be rendered invalid. You may also register 
online at behringer.com.