B&B Electronics Computer Accessories 3PCISD4A User Manual

Page of 27
 
Documentation Number 3PCISD4x-3903 Manual 
Appendix B 
B-1 
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445  
Appendix B:  Jumper Mode Tables 
Port A Jumper Settings Mode Table 
Jumpers 
Port  A (1) 
RS-232 RS-422 
4-wire 
RS-485 
4-wire 
RS-485 
2-wire 
JP1             
(4 Jumpers) 
232 422 422 422 
JP3A 
MODE 
232 
422/485 422/485 422/485 
JP3B RX 
not used 
422 
422 
485 
JP3C TX 
not used 
422 
485 
485 
JP3D (SD/RTS) 
(typical) 
not used 
not used 
RTS/SD 
SD 
RTS/SD 
SD 
JP3E - Term  
120
Ω
 (typical) 
not used 
IN/OUT 
OUT 
IN/OUT 
OUT 
IN/OUT 
OUT 
JP5 Clock       
(x4 or x1) 
(typical) 
*4/*1 
 
*1 
*4/*1 
 
*1 
*4/*1 
 
*1 
*4/*1 
 
*1 
 
How to use the table:  The left vertical column shows the jumpers 
for port A.  The right 4 vertical columns show the position setting of 
the jumper at the left for RS-232, RS-422 or 4-wire RS-485 or 2-wire 
RS-485 modes. 
 
NOTES: 
Refer to the Setup section for explanations of the RTS/SD, 
Termination and Clock settings.  All ports share the Clock setting.  
RS-485 Mode:  The SD/RTS jumpers should be set to automatic SD 
unless your software requires RTS Control. 
Note that termination should only be used in systems with both high 
baud rates (>19200) and over several thousand feet of cable. 
Information on RS-422 and RS-485 communications can be found in 
the B&B Electronics RS-422/485 Application Note (available on our 
Website). 
B-2 
Appendix B 
Documentation Number 3PCISD4x-3903 Manual 
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph 353-91-792444 – Fax 353-91-792445  
 
 
Port B Jumper Settings Mode Table 
Jumpers 
Port B (2) 
RS-232 RS-422 
4-wire 
RS-485 
4-wire 
RS-485 
2-wire 
JP2             
(4 Jumpers) 
232 422 422 422 
JP4A 
MODE 
232 
422/485 422/485 422/485 
JP4B RX 
not used 
422 
422 
485 
JP4C TX 
not used 
422 
485 
485 
JP4D (SD/RTS) 
(typical) 
not used 
not used 
RTS/SD 
SD 
RTS/SD 
SD 
JP4E - Term  
120
Ω
  
(typical) 
not used 
IN/OUT 
OUT 
IN/OUT 
OUT 
IN/OUT 
OUT 
JP5 Clock       
(x4 or x1) 
(typical) 
*4/*1 
 
*1 
*4/*1 
 
*1 
*4/*1 
 
*1 
*4/*1 
 
*1 
 
How to use the table:  The left vertical column shows the jumpers 
for Port B.  The right 4 vertical columns show the setting of the 
jumper at the left for RS-232, RS-422 or 4-wire RS-485 or 2-wire 
RS-485 modes. 
 
NOTES: 
Refer to the Setup section for explanations of the RTS/SD, 
Termination and Clock settings.  All ports share the Clock setting.  
RS-485 Mode:  The SD/RTS jumpers should be set to automatic SD 
unless your software requires RTS Control. 
Note that termination should only be used in systems with both high 
baud rates (>19200) and over several thousand feet of cable. 
Information on RS-422 and RS-485 communications can be found in 
the B&B Electronics RS-422/485 Application Note (available on our 
Website).