RS-232 Mode 
To configure Port 1 for RS-232 mode, 5 jumpers must be checked.  
The following settings will configure Port 1 as RS-232. 
1.  Set the four jumpers of JP1 to the "232" (left) position. 
2. 
 
Set the first jumper of JP3 (A) to the "232" (left) position. 
The remaining jumpers of JP3 are unused in the RS-232 mode and 
may be in either position. 
 
RS-422 Mode 
Nine jumpers must be set/checked to configure each Port to the  
RS-422 mode.  To set Port 1 for RS-422, set as follows below: 
1.  Set the four jumpers on JP1 to the "422" (right) position. 
2.
 
Set the top jumper of JP3 (A) to the "422/485" (right) position. 
3.
 
Set the second and third jumpers of JP3 (B) & (C) to the "422" 
(right) position. (These constantly enable receive & transmit.) 
4.
 
The fourth jumper JP3 (C) is unused in the RS-422 mode. 
(Selects RTS/SD for 485 mode) 
5.
 
The bottom jumper of JP3 (E) switches the 120
Ω
 receiver 
termination resistor IN or OUT. Typically this resistor is not used.  
In some cases using high baud rates and very long cables, 
termination is needed. See our RS-422/485 Application Note
6.
 
Configure each port as above using the table in Appendix B. 
Table 7:  RS-232 Pinouts 
RS-232 Signal 
Description 
Direction 
DB9M Pin 
DCD Data 
Carrier 
Detect input  1 
RD Receive 
Data 
input  2 
TD Transmit 
Data 
output  3 
DTR 
Data Terminal Ready 
output 
GND Signal 
Ground 
---- 
DSR Data 
Set 
Ready 
input  6 
RTS Request 
to 
Send  output  7 
CTS Clear 
to 
Send 
input  8 
RI Ring 
Indicator 
Input  9 
Chapter 2 
Documentation Number 3PCISD4x-3903 Manual 
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445  
RS-422/RS-485 Pinouts 
 
The RS-422 mode supports 2 channels (transmit and receive). 
 
 
 
With 2-wire RS-485 mode operation, your connection cable 
must jumper RD(A) to TD(A) and RD(B) to TD(B).  Connect from 
TD(A) & TD(B) to the Data A(
) and Data B(+) wires of your RS-485 
network. 
 
The EIA RS-422 Specification labels data lines with an "A" and 
"B" designator.  Some RS-422 equipment uses a "
" and "+" 
designator.  In almost all cases, the "A" line is the equivalent of the  
"
" line and the "B" line is the equivalent of the "+" line.  More 
information on RS-422 communications can be found in our free RS-
422/485 Application Note
 (available on our websites). 
RS-485 Mode 
For a 4-wire RS-485 single master system, the card can be set as in 
the RS-422 mode  (full duplex, transmit & receive enabled). 
Nine jumpers must be set/checked to configure each Port to the RS-
485 mode.  To set Port 1 for RS-485, set as follows below: 
1.
 
Set the four jumpers on JP1 to the "422" (right) position. 
2.
 
Set the top jumper of JP3 (A) to the "422/485" (right) position. 
3.
 
For 2-wire mode, set the second jumper, JP3(B) to the "485" 
(left) position (half duplex).  For 4-wire mode, set it to the "422" 
(right) position (full duplex, receive enabled). 
4.
 
Set the third jumper, JP3 (C) to the "485" (left) position. 
Table 8:  RS-422/RS-485 Pinouts 
RS-422 
Signal 
Description Direction DB9M 
Pinout 
--   -- 
RD(A) 
 
Receive Data A 
input 
TD(A) 
 
Transmit Data A 
output 
--   -- 
GND Signal 
Ground  ---- 
--   -- 
TD(B) + 
Transmit Data B 
output 
RD(B) + 
Receive Data B 
input 
--  NA