Brinkmann 842-0200-0 User Manual

Page of 8
Watch for Bubbles
4
Step 1
Assemble stove per "Assembly Instructions" on page 3
of this manual. Make sure burner control knobs are in
"OFF" position.
Step 2
Prepare a soapy water solution (one part dishwashing
liquid to three parts water) to test for gas leaks in the
connections. Apply a generous amount of the soapy
mixture to the regulator assembly at the regulator,
along entire length of hose, and at the stove fitting
(located on the right side of stove).
Step 3
With the burner control knobs in the "OFF" position,
check for bubbles where propane canister attaches to
regulator assembly, along entire length of hose, and at
stove fitting. If soapy mixture starts bubbling, gas is
leaking through the connections. Disconnect the
propane canister. Retighten the connection that is
leaking gas. Repeat procedure with soapy mixture until
gas no longer leaks. NEVER USE A FLAME TO CHECK
FOR GAS LEAKS.
Step 4
Once all gas leaks have been sealed, WAIT AT LEAST 5
MINUTES FOR GAS FUMES TO DISSIPATE BEFORE
LIGHTING THE BURNERS.
Carefully follow "Operating Instructions" to light the
burner and properly operate this unit.
GAS LEAK TESTING
Regulator Assembly
Regulator
WARNING
• Gas leak testing must be performed outdoors in a well ventilated area every time cylinder is connected to stove.
• Always keep unit away from open flames, sparks or lit cigarettes.
• Never use a flame to check for gas leaks.
• Never use a unit that has a gas leak. Contact The Brinkmann Corporation’s Customer Service Department for
replacement parts or repairs at 1-800-527-0717.
Stove Fitting
842-0200-0_Camp Stove-SS.qxd  3/17/03  4:53 PM  Page 5