White Rodgers 1F82-261 White-Rodgers 80 Series Programmable Heat Pump Thermostat Wiring Reference

Page of 1
L
R
E
24 VAC
120 VAC
Hot
SYSTEM
MONITOR
SWITCH
Neutral
SYSTEM
G
W2
Single transformer systems
TRANSFORMER
(Class II)
Changeover
Relay*
C
Y
O/B
Compressor
Contactor
* Changeover Relay is energized in COOL when O/B switch is in the “O” position
Changeover Relay is energized in HEAT when O/B switch is in the “B” position
Aux
Relay
(Stage 2)
Fan
Relay
Emergency
Relay
See Note **
** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
L
R
E
24 VAC
120 VAC
Hot
SYSTEM
MONITOR
SWITCH
Neutral
SYSTEM
G
W2
Two transformer systems with NO safety circuits
TRANSFORMER
(Class II)
Changeover
Relay*
C
Y
O/B
Compressor
Contactor
* Changeover Relay is energized in COOL when O/B switch is in the “O” position
Changeover Relay is energized in HEAT when O/B switch is in the “B” position
Aux
Relay
(Stage 2)
Fan
Relay
Emergency
Relay
Limit or
Safety
Switches
TWO COMMONS MUST
BE JUMPERED TOGETHER!
HOT
NEUTRAL
120 VAC
24 VAC
CUT AND
TAPE OFF!
If  safety  circuits  are  in 
only one of the systems, 
remove  the  transformer 
of  the  system  with 
NO 
safety circuits.
NOTE
** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
See Note **
1F82-261 / 1F89-211
Electric/Gas
jumper (W904)
O/B
switch
Reset switch
(below Fan switch)
W904
The following table allows you to customize the options on your Comfort-Set thermostat. Begin by pressing simultaneously the 
two buttons in step 1.
Electric / Gas Jumper (Fan Option)
If your emergency or auxiliary system will energize the blower, then 
jumper W904, on the thermostat base, must be cut (see figure at
left). If your emergency or auxiliary heat system requires that the
thermostat energize the fan circuit, do not cut jumper W904.
O/B Terminal Switch Selection
The O/B switch on this thermostat is factory set to the “O” position. 
This will accommodate the majority of heat pump applications, which
require the changeover relay to be energized in COOL. If the ther-
mostat you are replacing or the heat pump being installed with this 
thermostat requires a “B” terminal, to energize the changeover relay
in HEAT, the O/B switch must be moved to the “B” position.
CONFIGURATION AND
TYPICAL WIRING DIAGRAMS
CONFIGURATION
TYPICAL WIRING DIAGRAMS
1
 
 
 
Displayed (Factory Default)  Press          or          to select:            
COMMENTS
HOLD
(0:00)
0 to 8 hrs (in 
15 minute increments)
2
(SL)
FA
Select temporary Hold time
5
6
E
(on)
OFF
7
8
 LOC
(OFF)
on
0 HI
(0)
4 LO to
4 HI
°(F)
 °C
Returns to normal operation
9
11
Select Energy Management Recovery OFF or ON
Select Compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to °F or °C
Set
 SYSTEM
switch to OFF
or
4
d-L
(on)
OFF
Select display backlight OFF or ON
Filter
(000)
0 to 1950 hours
(in 50 hour increments)
Select filter replacement run time
Select FA or SL (Fast or Slow) pump cycle rate
Configuration Menu
* Press 
HOLD to advance to next item or TIME to move backwards to previous item
3
EMER
(FA)
SL
Select FA or SL (Fast or Slow) Auxiliary and 
Emergency Aux heating cycle rate
1F89-211
Press Button(s)
Step
RUN
PRGM
and
 RUN
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
1F82-261
Press Button(s)
or
or
or
or
or
or
or
HOLD*
FA (ON)
OFF
10
Selects fast second stage ON or OFF
HOLD*
or
www.white-rodgers.com
158
TECHNICAL
 HELP