White Rodgers 1F83-277 User Manual

Page of 10
1F83-277
1F83-277
1F83-277
1F83-277
1F83-277
Heating & Air Conditioning
Non-programmable, Auto Changeover, Multi-Stage/Heat
Pump Thermostat
PART NO. 37-6509A
PART NO. 37-6509A
PART NO. 37-6509A
PART NO. 37-6509A
PART NO. 37-6509A
0405
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Operator:  Save these instructions for future use!
Operator:  Save these instructions for future use!
Operator:  Save these instructions for future use!
Operator:  Save these instructions for future use!
Operator:  Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
INJURY AND/OR PROPERTY DAMAGE.
INJURY AND/OR PROPERTY DAMAGE.
INJURY AND/OR PROPERTY DAMAGE.
INJURY AND/OR PROPERTY DAMAGE.
PREPARATIONS
PREPARATIONS
PREPARATIONS
PREPARATIONS
PREPARATIONS
REMOVING OLD THERMOSTAT
REMOVING OLD THERMOSTAT
REMOVING OLD THERMOSTAT
REMOVING OLD THERMOSTAT
REMOVING OLD THERMOSTAT
Description
Description
Description
Description
Description
Heat Pump (No Aux. or Emergency Heat)
Yes
Heat Pump (with Aux. or Emergency Heat)
Yes
Standard Heat & Cooling Systems
Yes
Two Stage Heat & Two Stage Cool
Yes
Standard Heat Only Systems
Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces
Yes
Standard Central Air Conditioning
Yes
Gas or Oil Heat
Yes
Electric Furnace
Yes
Hydronic (Hot Water) Zone Heat – 2 Wires
Yes
Hydronic (Hot Water) Zone Heat – 3 Wires
No
White-Rodgers is a division 
of Emerson Electric Co.
www.white-rodgers.com
Before removing wires from old thermostat's switching sub-
base,  label each wire
label each wire
label each wire
label each wire
label each wire with the terminal designation it was
removed from.
1. Shut off electricity at the main fuse box until installation is
complete. Ensure that electrical power is disconnected.
2. Remove Old Thermostat
Remove Old Thermostat
Remove Old Thermostat
Remove Old Thermostat
Remove Old Thermostat: A standard heat/cool
thermostat consists of three basic parts:
a. The cover, which may be either a snap-on or
hinge type.
b. The base, which is removed by loosening all
captive screws.
c. The switching subbase, which is removed by
unscrewing the mounting screws that hold it on
the wall or adaptor plate.
3. Remove the front cover of the old thermostat. With
With
With
With
With
wires
wires
wires
wires
wires  still attached
still attached
still attached
still attached
still attached, remove wall plate from the wall. If
the old thermostat has a wall mounting plate, remove the
thermostat and the wall mounting plate as an assembly.
4. Identify each wire attached to the old thermostat.
5. Disconnect the wires from the old thermostat one at a
time. DO NOT LET WIRES FALL BACK INTO THE
DO NOT LET WIRES FALL BACK INTO THE
DO NOT LET WIRES FALL BACK INTO THE
DO NOT LET WIRES FALL BACK INTO THE
DO NOT LET WIRES FALL BACK INTO THE
WALL
WALL
WALL
WALL
WALL.
6. Install new thermostat using the following procedures.
Assemble tools required as shown below.
YOUR THERMOSTAT REPLACES
YOUR THERMOSTAT REPLACES
YOUR THERMOSTAT REPLACES
YOUR THERMOSTAT REPLACES
YOUR THERMOSTAT REPLACES
To prevent electrical shock and/or equipment dam-
To prevent electrical shock and/or equipment dam-
To prevent electrical shock and/or equipment dam-
To prevent electrical shock and/or equipment dam-
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
age, disconnect electric power to system at main fuse
age, disconnect electric power to system at main fuse
age, disconnect electric power to system at main fuse
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
or circuit breaker box until installation is complete.
or circuit breaker box until installation is complete.
or circuit breaker box until installation is complete.
or circuit breaker box until installation is complete.
CAUTION
!
Figure 1 – Thermostat base
Figure 1 – Thermostat base
Figure 1 – Thermostat base
Figure 1 – Thermostat base
Figure 1 – Thermostat base
ATTENTION!
ATTENTION!
ATTENTION!
ATTENTION!
ATTENTION!  This product does not contain mercury. How-
ever, this product may replace a unit which contains mercury.
Do not open mercury cells. If a cell becomes damaged, do not
not
not
not
not
touch any spilled mercury. Wearing non-absorbent gloves,
clean up the spilled mercury and place into a container which
can be sealed. If a cell becomes damaged, the unit should be
discarded.
Mercury must not be discarded in household trash. When the
unit this product is replacing is to be discarded, place in a
suitable container and return to White-Rodgers at 2895 Harrison
Street, Batesville, AR 72501 for proper disposal.
HAND OR POWER 
DRILL WITH 3/16 INCH 
DRILL BIT, IF NEEDED
SPIRIT LEVEL OR PLUMB BOB AND LINE OPTIONAL— 
THERMOSTAT DOES NOT NEED TO BE LEVEL TO WORK PROPERLY
FLAT BLADE SCREWDRIVER
WIRE CUTTER/STRIPPER
Mounting
Hole
Elec-Gas
Switch
Mounting
Hole
AUTO
ON
ELEC.
GAS
C
O
B
L
W2 G
Y2
R
E/W1
Y1