White Rodgers 21V51U-843 Universal Two-stage HSI Integrated Furnace Control Kit Installation Instruction

Page of 8
5
The 50V51-843 has only one serviceable part –an automotive 
type fuse, which protects the low voltage transformer from dam-
age if the output is short-circuited. If the fuse has opened up, 
remove whatever caused the short circuit and replace the fuse 
with only a 3 amp automotive type fuse. If the fuse is not the 
cause of the control’s problem, replace the entire 50V51-843 
control. There are no other user serviceable parts. 
Following installation or replacement, follow appliance manu-
facturer’s recommended installation or service instructions to 
insure proper operation.
Y
W1
W2
G
R
O
B/C
DEHUM
YLO
R
G
W2
W1
Y2
Y
THERMOSTAT
50V51-843 TYPICAL SYSTEM WIRING DIAGRAM
Low Voltage (24 VAC)
Line Voltage (120 VAC)
LEGEND
N.C. = Normally closed switch
N.O. = Normally closed switch
HOT
(LINE)
NEUTRAL
(LINE)
120 VAC
24 VAC CLASS II
TRANSFORMER
50V51-843
24 VAC
TH
TR
LINE
XFMR
EAC
HUM
CIRC N
HUM N
LINE N
XFMR N
EAC N
E2
HUMIDIFIER
(OPTIONAL)
ELECTRONIC
AIR CLEANER
(OPTIONAL)
CONDENSING
UNITS
FLAME
SENSOR
PROBE
2ND STAGE PRESSURE
SWITCh (N. O.)
HIGH LIMIT
(N. C.)
AUX. HIGH
LIMIT (N. C.)
1ST STAGE PRESSURE
SWITCh (N. O.)
GAS
VALVE
HLO
HLI
FP
PS1
MVL
MVH
GND
GND
PS2
MV COM
TR
TH
INDUCER
IGNITOR
IGN
IND HI
IND LO
IND N
IGN N
ROLLOUT
SWITCh (N. C.)
CIRCULATOR
CIRC.
INTER-
FACE
[5-Pin Connector]
[12-Pin Connector]
MVH
HLO
TH
PS2
GND
GND
MVL
FP
HLI
TR
PS1
MV
COM
IGN
IND
LO
IND
N
IND
HI
IGN
N
5-Pin Connector
12-Pin Connector
 
 WIRING