Whirlpool WET3300XQ Quick Setup Guide

Page of 44
7
DRAIN SYSTEM
Drain system can be installed using a floor drain, wall standpipe,  
floor standpipe, or laundry tub. Select method you need.
Floor standpipe drain system
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum 
carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe 
must be at least 39" (990 mm) high; install no higher than 96"  
(2.4 m) from bottom of washer/dryer. If you must install higher 
than 96" (2.4 m), you will need a sump pump system.
Wall standpipe drain system
See requirements for floor standpipe drain system.
Floor drain system
Floor drain system requires a Siphon Break Kit (Part Number 
285834), 2 Connector Kits (Part Number 285385), and an  
Extension Drain Hose (Part Number 285863) that may be  
purchased separately. To order, please see toll-free phone  
numbers in your Use and Care Guide. Minimum siphon break: 
28" (710 mm) from bottom of washer/dryer. (Additional hoses 
may be needed.)
Laundry tub drain system
Minimum capacity: 20 gal. (76 L). Top of laundry tub must be  
at least 39" (990 mm) above floor; install no higher than 96"  
(2.4 m) from bottom of washer/dryer. 
IMPORTANT: To avoid siphoning, no more than 4.5" (114 mm) 
of drain hose should be inside standpipe or below the top of 
wash tub. Secure drain hose with shipping strap.