Table 1:  Alliance Water Heater Dimension (Inches)
Table 2:  Alliance Water Heater Capacities
Table 3:  Alliance Water Heater Performance
ALL IA NCE
MODEL
A
B
C
D
E
F
G
H
I
J
K
AL 26A
40
20-1/4
31-1/2
22-1/2
9-3/4
2
3/4
3/4
3/4
3/4
3/4
AL 40A
55
20-1/4
46-1/2
25-3/4
9-3/4
2
3/4
3/4
3/4
3/4
3/4
AL 53A
70-5/8
20-1/4
62-1/8
28-3/4
9-3/4
2
3/4
3/4
3/4
3/4
3/4
AL 79A
69-3/8
23-3/4
60-7/8
29-1/4
10-1/4
1-5/8
1
3/4
3/4
1
1
AL119A
66
29-1/2
52-3/4
39-1/4
12-3/4
2-1/2
1-1/4
1-1/4
1-1/4
1-1/4
1
ALLIANCE
MODEL
TANK
VOLUME
(GAL)
COIL
VOLUME
(GAL)
DRY
WEIG HT
(LB S)
WET
WEIG HT
(LB S)
COIL HEAT
TRANSFER
AREA ( SQ. FT.)
M AXIMUM
ALLOWA BLE
WORKING
P RESSURE ( PSI)
HYDRO STATIC
DESIGN
P RESSURE ( PSI)
AL 26A
26.4
1.0
49
269
6.5
150
300
AL 40A
39.6
1.2
66
396
8.6
150
300
AL 53A
52.8
1.4
82
522
9.7
150
300
AL 79A
79.3
2.2
170
831
15.1
150
300
AL119A
119.4
2.9
183
1178
24.3
150
300
MO DE L
M A X IM U M   FIR S T
HO UR  RAT IN G
G A L/ HR   @
CO NT IN UO U S
RAT IN G
G A L /M IN   @
B O IL E R  D O E
H E AT IN G  C A PA CI T Y
N E E DE D   F O R
R AT I NG S   (B T U/ HR )
M I NI M UM   B O I LE R
W AT E R  F LO W
TH R O U G H  HE AT E R
C O IL  (G A L /M IN )
P R E S S UR E
D RO P   T H RO U G H
C O I L  AT   M IN .
FL O W   (F T.  W .C .)
M IN UT ES   O F
1 40 F   W AT E R
AVA IL A B L E   AT
5   G P M   D RA W
14 0 F
11 5 F
14 0 F
11 5 F
A L 2 6 A
1 42
1 97
1. 93
2. 84
11 0 ,0 00
8 .0
2 .5
2 .4
A L 4 0 A
1 75
2 42
2. 26
3. 38
13 3 ,0 00
11 .4
6 .1
7 .2
A L 5 3 A
2 24
3 10
2. 85
4. 29
16 4 ,0 00
10 .9
6 .5
9 .0
A L 7 9 A
2 53
3 50
2. 90
4. 51
19 0 ,0 00
10 .6
8 .4
9 .1
A L 11 9 A
3 50
4 09
3. 84
4. 83
38 6 ,0 00
15 .4
11 .6
16 .4
N O T E S :   
A l l  ra tin g s  b a s e d   o n   2 0 0 F   b o ile r  w a te r  t e m p e ra t u re ,   5 0 F   d o m e s t ic  w a te r   in le t  te m p e ra tu r e ,   a n d   a   f u lly   re c o ve r e d
t a n k  (w h e n   a p p lic a b le ).