Whirlpool WFG114SWB Quick Setup Guide
13
3. Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
compartment.
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
4. Remove the cap from the gas pressure regulator using a
flat-blade screwdriver.
NOTE: Make sure sealing washer remains in the same
position.
position.
5. To convert to LP gas, unscrew the plastic adjustment screw
by hand, turn it over, and screw it in again.
6. Reinstall the cap.
To Convert Surface Burners
1. Remove burner grate, burner caps and burners.
2. Locate LP gas orifice spuds for top burners in the literature
bag included with the range. Three LP gas spuds are
stamped “88” and one “96.”
stamped “88” and one “96.”
3. Remove Natural gas orifice spuds using a 7 mm combination
wrench.
4. Install LP gas orifice spuds using a 7 mm combination
wrench.
NOTE: Depending on model, the range cooktop may be
equipped with 4 standard burners or 3 standard burners and
1 super burner. Spud size and location remain the same.
equipped with 4 standard burners or 3 standard burners and
1 super burner. Spud size and location remain the same.
A. Gas pressure regulator
A. Cap
Inlet pressure
to Natural gas
to Natural gas
Inlet pressure
to LP gas
to LP gas
A. Cap
B. Sealing washer
B. Sealing washer
C. Adjustment screw
A
A
A
C
B
180º
A. Burner cap
B. Burner
B. Burner
A. Spud
B. Holder
B. Holder
A
B
A
B