11 
There is no Auto Negotiation in either of the Force modes. 
Auto Negotiation (ISA Version) 
When connecting two McPC 10/100s between two end stations (devices such as 
switches, hubs and repeaters), all devices in the media conversion should ideally 
support, and be utilizing, Auto Negotiation functionality. While it is possible to have 
Auto Negotiating devices on one side of the media conversion and fixed (non-Auto 
Negotiating) devices on the other, link LEDs will react differently depending on where 
a link fault occurs. Therefore, IMC recommends: 
 
•  Configuring every device in the media conversion for Auto Negotiation. 
 
•  For installations where Auto Negotiation is NOT possible from one end of the 
media conversion to the other, manually configure all devices for 10 Mbps or 
100 Mbps connections. 
Transparency (ISA Version) 
Transparency is only available when using Auto Negotiation mode; it is not available 
in either of the two Force modes.  When the McPC 10/100 is Auto Negotiating, 
Transparency treats the connection between the two end devices as if there were no 
media converters installed.  For example, in a typical application where two media 
converters are installed between two copper-based switches, the twisted pair cables 
as well as the fiber cable are seen as a single entity.  Therefore, if a fault occurs on 
any segment between the two end devices, link LEDs on the end devices will go out. 
 
Transparency is available when the McPC 10/100 is operating in Auto Negotiation 
mode. Therefore 6 Auto Negotiation must be ON and 5 (LFD), 7 (Force) and 8 (10 or 
100) must be OFF
 
Transparency 
 
 
Link Fault Detection (ISA Version) 
Link Fault Detection (LFD) is only available when using Force 10 or Force 100 mode. 
It is not available in Auto Negotiation mode.  When LFD is enabled and the input link 
is down at one interface to the McPC 10/100, the transmitter output on that interface 
will blink.  It applies to both network interfaces and to both data rates.  If the link at 
the other interface to the McPC 10/100 is also down, there is no output.  LFD causes 
the Link Up indicator of the link partner to blink.