TROUBLESHOOTING (cont.)
Unit is not working
Difficulty brixing and/or weak bev-
erage
Difficulty brixing and/or weak bev-
erage
Difficulty brixing bag-in-box
1. Step-down transformer.
2. Main control board.
1. Product viscosity or too cold.
2. Low water pressure.
3. High water pressure.
4. Dispense valve adjustment set-
ting.
5. Brix ratio.
1. Pump tubing.
2. Use of portable water pump.
Vacuum leak
Check for 120/24 or 230/24 vac. If no 
24vac reading, replace step-down 
transformer.
If 24 vac present and no LED’s lit, 
replace control board..
Thorough thaw of product before 
use (35° - 40°)
Maintain  20  psi  or  higher  and  a 
minimum flow rate of 3 fl oz/sec.
Over  100  psi,  install  a  pressure 
regulator and set to 50 psi.
A) Perform 3 second water dispense 
test. Factory setting is 1.0 oz/sec. 
Acceptable water flow rate is .-0.8 
to 1.5 oz/sec depending on the mix 
ratio (4+1).
B) Adjust water to proper mix ratio. 
Once  water  is  set,  adjust  motor 
speed to achieve brix %.
Check for proper brix ratio per prod-
uct  using  Total  Dispense  method 
and or refractometer method.
Inspect,  clean,  or  replace  tubing 
and pump rotor/rollers for ease of 
rotation.
A) Follow plumbing requirements 
for pressure and flow rate.
B) Source another portable pump 
or water supply that meets require-
ments.
Inspect  all  lines  and  connections 
from bag-in-box connector to bottle 
adapter assembly.