Heath Zenith SL-9526 User Manual

Page of 16
3
598-1147-00
Motion
Motion
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
Sensor
The detector is most sensitive to motion across its field
of view.
Loosen the clamp screw in the
sensor ball joint and gently ro-
tate the sensor.
Walk through the coverage area
noting where you are when the
lights turn on (also, the LED will
flash several times when mo-
tion is detected). Move the sen-
sor head up, down, or sideways
to change the coverage area.
Keep the sensor at least 1"
(2.5 cm) away from the lamps.
Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 10 minutes).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . . .  Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . .  Up to 180
°
Electrical Load . . . . . . . .  Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements . . .  120 VAC, 60 Hz
Operating Modes . . . . . .  TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . .  1 , 5, 10 minutes
DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
NOTE:
Sensor has about 1 
1
/
2
  minutes warm up
period before it will detect motion. When first
turned on, wait about 1 
1
/
2
 minutes.
RANGE
10 5 1 TEST
ON-TIME
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners.  These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
180
°
MIN
MAX
70 ft.
(21 m)
8 ft.
(2.4 m)
Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
Least Sensitive
 Most Sensitive
Maximum Range
Maximum
Coverage Angle