Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
DANGER
If you smell gas -
1. Shut off gas to appliance.
2. Extinguish any open flame.
3.  If odor continues, keep away from the appliance immediately and call 
your gas supplier or your fire department.
WARNING
FOR YOUR SAFETY
1.  Do not store or use gasoline or other flammable liquids or vapors in the 
vicinity of this or any other appliance.
2.  An LP cylinder not connected for use shall not be stored in the vicinity 
of this or any other appliance.
  This SkeeterVac
®
 is for outdoor use only, and shall not be used in a 
building, garage, or any other enclosed area.  
  Do NOT operate, light or use this appliance within 8 feet of walls, 
structures, buildings or combustible materials.
   It is a violation of Federal law to use this product in a manner 
inconsistent with its labeling.
  This SkeeterVac
®
 is NOT for commercial use.
  This SkeeterVac
®
 is for use with liquid propane (LP) gas only. 
The conversion to or attempted use of natural gas in this LP gas 
SkeeterVac
®
 is dangerous and will void your warranty.
   LP gas Characteristics: 
  a.  LP gas is flammable and hazardous if handled improperly.  Become 
aware of the characteristics before using any LP gas product.  
  b.  LP gas is explosive under pressure, heavier than air, and settles and 
pools in low areas. 
  c.  LP gas in its natural state has no odor.  For your safety, an odorant is 
added that smells like rotten cabbage.  
  d. Contact with LP gas can cause freeze burns to skin.
   LP gas tank needed to operate. Only tanks marked “propane” may be 
used.  
  a.  The LP gas supply tank must be constructed and marked in 
accordance with the Specifications for LP gas Cylinders of the 
U.S. Department of Transportation (DOT) or the National Standard 
of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for the 
Transportation of Dangerous Goods; and Commission.  
  b. LP gas tank must be arranged for vapor withdrawal.
  c.  The LP gas tank must have a listed overfilling prevention device 
(OPD).
  d.  Only use 20-pound cylinders equipped with a cylinder connection 
device compatible with the connection for outdoor cooking 
appliances.
  e. The LP gas tank must have a tank collar to protect the tank valve.
  f.  Never use an LP gas tank with a damaged body, valve, collar, or 
footing.  
  g.  Dented or rusted LP gas tanks may be hazardous and should be 
checked by your LP gas supplier prior to use.
  h.  The LP gas tank should not be dropped or handled roughly. 
  i.  Tanks must be stored outdoors out of the reach of children and must 
not be stored in a building, garage, or any other enclosed area. Your 
tank must never be stored where temperatures can reach over 125°F. 
  j.  Never keep a filled LP gas tank in a hot car or car trunk. Heat will 
cause the gas pressure to increase, which may open the relief valve 
and allow gas to escape.
  k.  Place dust cap on cylinder valve outlet whenever the cylinder is not in 
use. Only install the type of dust cap on the cylinder valve outlet that 
is provided with the cylinder valve. Other types of caps or plugs may 
result in leakage of propane.
  l. Do not store a spare LP gas tank under or near this appliance.
  m.  Never fill the tank beyond 80 percent full.
  n.  A fire causing, serious injury or damage to property may occur if the 
above is not followed exactly. 
  o.  Always transport your tank in a secure, well-ventilated location in 
your vehicle. LP gas tank should be upright with valve turned off. LP 
gas tank should be taken directly to and from place of use.
  Never attempt to attach this SkeeterVac
®
 to the self-contained LP gas 
system of a camper trailer, motor home, or house.  
  The use of alcohol, or prescription or non-prescription drugs may 
impair the consumer’s ability to properly assemble or safely operate the 
appliance.
  Your SkeeterVac
®
 has been checked at all factory connections for 
leaks.  Recheck all connections, as movement in shipping can loosen 
connections.  
  Check for leaks even if your unit was assembled for you by someone 
else.
  Do not operate if gas leak is present. Gas leaks may cause a fire or 
explosion.
  You must follow all leak-checking procedures before operating. To 
prevent fire or explosion hazard when testing for a leak:
  a.  Always perform leak test before lighting the SkeeterVac
®
 and each 
time the tank is connected for use.
  b.  No smoking.  Do not use or permit sources of ignition in the area 
while conducting a leak test. 
  c.  Conduct the leak test outdoors in a well-ventilated area.  
  d.  Do not use matches, lighters, or a flame to check for leaks.  
  e.  Do not use SkeeterVac
®
 until any and all leaks are corrected.   
If you are unable to stop a leak, disconnect the LP gas supply.  Call a 
gas appliance serviceman or your local LP gas supplier.
  Do not store or use gasoline or other flammable liquids or vapors within 
25 feet (7.62 m) of this appliance.
  Do not use in an explosive atmosphere.  Keep SkeeterVac
®
 area clear 
and free from combustible materials, gasoline and other flammable 
vapors and liquids.  
  Minimum clearance from sides and back of unit to combustible 
construction, 21 inches from side and 21 inches from back. Do not use 
this appliance under overhead combustible surfaces.
  It is essential to keep the SkeeterVac®’s valve compartment, burners, 
and circulating air passages clean.  Inspect SkeeterVac® before each 
use.
  Do not alter SkeeterVac
®
 in any manner.
  Do not use the SkeeterVac
®
 unless it is COMPLETELY assembled and all 
parts are securely fastened and tightened. 
  This SkeeterVac
®
 should be thoroughly cleaned and inspected on 
a regular basis. Clean and inspect the hose before each use of the 
appliance.  If there is evidence of abrasion, wear, cuts, or leaks, the 
hose must be replaced prior to the appliance being put into operation.  
  Use only the regulator and hose assembly provided. The replacement 
regulator and hose assembly shall be that specified by the 
manufacturer.
  Use only Blue Rhino Global Sourcing, Inc. factory authorized parts. The 
use of any part that is not factory authorized can be dangerous. This 
will also void your warranty. 
  Do not use this appliance without reading “Operating Instructions” in 
this manual.  
 Do not install or use in or on boats or recreational vehicles.
  Product performance can vary due to weather, wind and other 
environmental conditions.
  Never lean over the SkeeterVac
®
 when lighting.
  Do not attempt to move SkeeterVac
®
 when in use.  Allow the 
SkeeterVac
®
 to cool before moving or storing.
  Storage of SkeeterVac
®
 indoors is permissible only if the tank is 
disconnected, removed from the SkeeterVac® and properly stored 
outdoors. 
  Do not attempt to disconnect the gas regulator from the tank or any gas 
fitting while the SkeeterVac
®
 is in use.
  Do not use SkeeterVac
®
 for indoor cooking or heating. TOXIC fumes can 
accumulate and cause asphyxiation. 
  After a period of storage and/or nonuse, check for leaks, burner 
obstructions and inspect for any abrasion, wear, cuts to the hose.
  If SkeeterVac
®
 is not in use, the gas must be turned off at the supply 
tank.
   Keep air intake areas clear of dust, dirt and debris
  Do not allow children to operate or play near a SkeeterVac
®
 device 
when it is in use.
  Inspect for damage and wear during each maintenance cycle.
  It is recommended to use only FineTune
®
 mosquito attractant in your 
SkeeterVac
®
.  The use of other attractants has not been tested with your 
product, and void your warranty. 
   Maximum inlet gas supply pressure is 11 inch water column
  Deaths, serious injury or damage to property may occur if the above is 
not followed exactly.
 DANGER:  Failure to follow the dangers, warning and cautions in this manual may result in serious bodily injury or death, or in a fire or an explosion 
causing damage to property.
 WARNING: