IBM CF Series User Manual

Page of 102
    

  *!#")!"! # %" )-,,"& "  
 "(!$""!"#" $!.(-+ #" +!! &
    "$""  (

"'+ +  #!#&#"+  + #
  (
I. "Terminal" Setup  
A. Open the "Terminal" program 
B. Under "Settings" 
1. “Terminal Emulation" - Select DEC VT-100 (ANSI) 
2. “Terminal Preferences" 
i. Select "Line Wrap" = NO  
(May be called "New Line") 
ii. Select "Local Echo" = NO 
iii. Select "CR->CR/LF " = NONE 
iv. Select Columns = 80 
v. Select "Terminal Font" = Courier 20 
vi. Select "Translations" = NONE 
vii. Select "Use Function, Arrow, and Ctrl Keys for Windows" = NO 
3. “Communications" 
i. Select "Baud Rate" = 9600 
ii. Select "Data Bits" = 8 
iii. Select "Stop Bits" = 1 
iv. Select "Parity" = NONE 
v. Select "Flow Control" = NONE 
vi. Select "Connector" = Must match the port with the serial cable connected to the 
scanner's HOST connection
C. The Diagnostic program only recognizes upper case letters, therefore the "CAPS LOCK
must be ON
II. Save the Setup 
A. Under "File" 
1. Select "Save As..." 
2. Save the settings as "terminal.trm" for automatic loading when the program starts.