Hunter UH68ODH User Manual

Page of 29
UH68ODK Tent Heater 
 
4-3 
Troubleshooting Procedures 
 
1.1  Fuel Supply – 
See PMCS 
 
1.2 Check Flame Switch – the flame switch is a 
normally open heat sensitive switch. The UH68G 
has two switches. As used in the 68 outdoor kit, 
only the normally open switch is active. Normally 
switch 1, red and brown wires, is used. The 
other switch is normally open and is not used. 
 
1.3  Check Fuel Pump – The fuel pump operates 
on 24vdc. Energize the pump and listen for 
operation. Remove outlet connector and check 
for fuel flow. Pump develops about 4 psi., if fuel 
slowly runs from pump, clean filter as defined in PMCS. If 
fuel runs out of pump at a good steady rate pump is ok. 
1.4 Check Fuel Flow at Carburetor – remove fuel needle (1), 
start heater. when combustion blower comes on fuel 
should run from the fuel needle hole. If not fuel flow has 
been stopped up stream. Check fuel solenoid and float 
bowl needle and seat. 
1.5 Check Ignition Transformer – CAUTION! The ignition 
transformer develops 10,000 volts. Disconect ignition 
cable form igniter. Position spring at tip of cable not more 
than 1/8 inch from grounded surface. Turn heater on. If no 
spark is detected, check power to igniton transformer. 
1.6 Check Overheat Thermostat – the overheat thermostat (1) 
is a normally closed temperature sensitive switch. Disconnect 
wires from switch, and check continuity across switch.