Brother BAS-300G-484/484SF Owner's Manual

Page of 66
9. TABLE OF ERROR CODES 
 
 
55 
KE-430D, BE-438D 
9. TABLE OF ERROR CODES 
     
DANGER
 
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet 
before opening the face plate of the control box. Touching areas where high voltages are present can result in 
severe injury.
 
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display 
window. Follow the remedy procedure to eliminate the cause of the problem. 
 
Switch-related errors 
Code 
Cause and remedy 
E025 
Foot switch is depressed to the 2nd step. 
Turn off the power and check the foot switch. 
E035 
Foot switch is depressed to the 1st step. 
Turn off the power and check the foot switch. 
E050 
Machine head tilting was detected after the power was turned on. 
Turn off the power, and then return the machine head to its original position. 
Check that connector P8 on the main P.C. board is properly connected. 
E051 
Machine head tilting was detected while the sewing machine was operating. 
Turn off the power, and then check that connector P8 on the main P.C. board is properly connected. 
E055 
Machine head tilting was detected when the power was turned on. 
Turn off the power, and then return the machine head to its original position. 
Check that connector P8 on the main P.C. board is properly connected. 
E065 
An operation panel key was still being pressed when the power was turned on, or key is faulty. 
Turn off the power and check the operation panel. 
 
Upper shaft motor-related errors 
Code 
Cause and remedy 
E100 
Sewing machine has continued to be used for a certain period after the “GREASEUP” notification appears 
without the grease being applied (without the reset procedure being carried out). 
Apply grease and then carry out the reset procedure. (Refer to the service manual for the reset procedure.) 
E110 
Needle up stop position error. 
Turn the pulley to align the index mark with the needle up stop position. 
E111 
Upper shaft did not stop at the needle up stop position when the sewing machine stopped. 
Turn the pulley to align the index mark with the needle up stop position. 
E120 
Needle drop signal could not be detected. 
Turn off the power, and then check the synchronizer connection. 
E121 
Thread trimming was not completed. 
Turn off the power, and then check if the cutting edges of the fixed knife and movable knife are damaged or worn.
E130 
Sewing machine motor stopped abnormally or synchronizer is not connected correctly. 
Turn off the power, and then turn the machine pulley to check if the machine has locked up. 
Check that connectors P4 and P5 on the power supply motor P.C. board are properly connected. 
E131 
Synchronizer is not connected correctly. 
Turn off the power, and then check that connector P5 on the power supply motor P. C. board is properly 
connected. 
E132 
Problem detected with sewing machine motor operation. 
Turn off the power, and then check that connector P4 on the power supply motor P.C. board is properly 
connected. 
E133 
Sewing machine motor stopping position is incorrect. 
Turn off the power, and then check that connector P5 on the power supply motor P.C. board is properly 
connected. 
E150 
Sewing machine motor is overheating, or temperature sensor is faulty.   
Turn off the power, and then check the sewing machine motor. 
(When sewing data with a small number of stitches (15 stitches or less) is sewn repeatedly (short cycle 
operation), the upper shaft motor may overheat and the “E150” error code may be generated.)