If your MFJ-1278B does not have the 2400 bps packet capability, then the user can easily 
install the proper hardware. The user can purchase the optional MFJ-2400 BPS modem, and 
is easily installed.  Installation is simple, because your MFJ-1278B is equipped with all the 
appropriate connectors necessary to make this installation quick and easy without 
modifications or soldering.  If you have the MFJ-1278BT the 2400 modem is already 
installed inside the unit. 
 
With the MFJ-2400 modem installed, your MFJ-1278B is capable of operating 300, 1200 or 
2400 baud packet.  With the MFJ-2400 BPS modem has no effect on the 300 and 1200 baud 
packet mode operations.  The addition of the 2400 modem feature will in no way require any 
internal modification to your transceiver. 
2400 BPS PACKET SETUP 
All the default parameter settings for 1200 baud packet operation can be used for 2400 bps 
packet operation.  2400 bps operations need no special setup or parameter changes.  There 
are however, some changes that the user can make later on to the MFJ-1278B parameters that 
will enable you to improve the speed of the throughput performance of the 2400 bps 
operation.  The "honing" of the parameters may not seem like much, but we have found that 
at 2400 bps, the MFJ-1278B seems to be more responsive to the  TXDELAY,  DWAIT
RESPONSE and SLOTTIMES.  When using direct connects and good paths, the user can 
increase the  MAXFRAME and  PACLEN commands to allow larger packets to be moved 
during each transmission.  When returning to the active throughput frequencies, these two 
commands should be reduced to their original settings.  You may find that if you were using a 
TXDELAY of  50, then a  TXDELAY of  40 will now perform better.  The  DWAIT 
command can be shortened or lengthened to suit the AGC recovery time of your radio.  For 
instance, if you have been running the DWAIT of 16, it may now perform better at DWAIT 
of 12 or even 10.  The FRACK will appear to exercise more at 2400 also. 
 
2400 BPS operation really shows its place in the packet world when used to pass large 
ASCII, BINARY and PICTURE files.  It is always good to use clear frequency and/or use 
direct connects to the target station rather than going thru a node or digipeater.  The reason is 
obvious.  There are few 2400 nodes at the present time.  However, it should be pointed out 
that implementation of a 2400 node is just as easy as building and using a 1200 node. 
 
To select 2400 packet operation, under the CMD: command prompt, type: 
 
MODE VP,2400  <CR> 
 
The MFJ-1278B changes its operating mode to 2400 bps packet.   The  TURBO  LED will