Step 19: CALIBRATION PROCESS (TC3000 and TC5000 only)
Assembly Guide
 
failure to calibrate your machine prior to use could result in machine failure  
and could cause injury.
during the entire calibration process, stand on the side foot support platforms or rubber 
mat only, do not stand on the walking belts! 
7 ! 2 . ) . '
! 4 4 % . 4 ) / .
$ ! . ' % 2
DO NOT STEP ON THE BELTS DURING 
THIS ENTIRE PROCESS.
Owners of the TC3000 or TC5000 will need to 
calibrate the TreadClimber
®
 machine before they 
can begin exercising. Owners of the TC1000 do not 
need to complete this step.
Calibrating the TC3000 and TC5000 is an important 
part of troubleshooting maintenance. 
 
 
 
NOTE:  You will also need to re-calibrate 
your machine in the event of 
a power outage or if you have 
replaced a TreadClimber
®
 
component, such as a belt, or 
motor.
19-1 Plug power cord into wall outlet.
19-2 Turn on Main Power Switch (see Figure 19-1).
19-3  Stand on the side foot support platforms or 
rubber floor mat, DO NOT STAND ON THE 
BELTS.
19-4  Insert the Safety Key, press and hold down the 
POWER button, then very quickly press and 
hold down the SLOWER button. Continue to 
hold down the POWER and SLOWER buttons 
(see Figure 19-2 for the TC5000 and Figure 
19-3 for the TC3000).  
 
NOTE:  If the Safety Key is not fully 
inserted into the safety keyhole, the 
TreadClimber
®
 machine will NOT 
power up. 
19-5  At this point you should see the numbers start 
to decrease on the console.
19-6  While continuing to hold down the POWER 
and SLOWER buttons, remove and re-insert 
the Safety Key.
Figure 19-1 
Main Power Switch “On”
Figure 19-2 
TC5000 Power & Slower Buttons
É
0/7%2
 
4/

*"7 ,


Figure 19-3 
TC3000 Power & Slower Buttons